diff mbox series

[v3,6/7] riscv: Update Kendryte device tree for new CLINT driver

Message ID 20200901103208.440316-7-seanga2@gmail.com
State Superseded
Delegated to: Andes
Headers show
Series riscv: Clean up timer drivers | expand

Commit Message

Sean Anderson Sept. 1, 2020, 10:32 a.m. UTC
AFAIK because the K210 clock driver does not come up until after
relocation, the clint will always use the clock-frequency parameter.
Ideally, it should update itself after relocation to take into account the
actual CPU frequency.

The interrupt controller property is removed from the clint binding because
the clint is not an interrupt-controller. That is, no other devices have an
interrupt which is controlled by the clint.

Signed-off-by: Sean Anderson <seanga2@gmail.com>
---

(no changes since v2)

Changes in v2:
- New

 arch/riscv/dts/k210.dtsi | 9 ++++++---
 1 file changed, 6 insertions(+), 3 deletions(-)
diff mbox series

Patch

diff --git a/arch/riscv/dts/k210.dtsi b/arch/riscv/dts/k210.dtsi
index 2546c7d4e0..2698a33a5c 100644
--- a/arch/riscv/dts/k210.dtsi
+++ b/arch/riscv/dts/k210.dtsi
@@ -17,6 +17,8 @@ 
 	compatible = "kendryte,k210";
 
 	aliases {
+		cpu0 = &cpu0;
+		cpu1 = &cpu1;
 		dma0 = &dmac0;
 		gpio0 = &gpio0;
 		gpio1 = &gpio1_0;
@@ -126,14 +128,15 @@ 
 			read-only;
 		};
 
-		clint0: interrupt-controller@2000000 {
+		clint0: clint@2000000 {
 			#interrupt-cells = <1>;
 			compatible = "kendryte,k210-clint", "riscv,clint0";
 			reg = <0x2000000 0xC000>;
-			interrupt-controller;
 			interrupts-extended = <&cpu0_intc 3>, <&cpu0_intc 7>,
 					      <&cpu1_intc 3>, <&cpu1_intc 7>;
-			clocks = <&sysclk K210_CLK_CPU>;
+			clocks = <&sysclk K210_CLK_CLINT>;
+			/* sysclk is only available post-relocation */
+			clock-frequency = <7800000>;
 		};
 
 		plic0: interrupt-controller@C000000 {