diff mbox series

[SRU,Hirsute] xfs: fix up non-directory creation in SGID directories

Message ID 20211116195627.482400-2-cascardo@canonical.com
State New
Headers show
Series [SRU,Hirsute] xfs: fix up non-directory creation in SGID directories | expand

Commit Message

Thadeu Lima de Souza Cascardo Nov. 16, 2021, 7:56 p.m. UTC
From: Christoph Hellwig <hch@lst.de>

BugLink: https://bugs.launchpad.net/bugs/1950239

XFS always inherits the SGID bit if it is set on the parent inode, while
the generic inode_init_owner does not do this in a few cases where it can
create a possible security problem, see commit 0fa3ecd87848
("Fix up non-directory creation in SGID directories") for details.

Switch XFS to use the generic helper for the normal path to fix this,
just keeping the simple field inheritance open coded for the case of the
non-sgid case with the bsdgrpid mount option.

Fixes: 1da177e4c3f4 ("Linux-2.6.12-rc2")
Reported-by: Christian Brauner <christian.brauner@ubuntu.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Darrick J. Wong <djwong@kernel.org>
Signed-off-by: Darrick J. Wong <djwong@kernel.org>
(cherry picked from commit 01ea173e103edd5ec41acec65b9261b87e123fc2)
Signed-off-by: Thadeu Lima de Souza Cascardo <cascardo@canonical.com>
---
 fs/xfs/xfs_inode.c | 14 +++++++-------
 1 file changed, 7 insertions(+), 7 deletions(-)
diff mbox series

Patch

diff --git a/fs/xfs/xfs_inode.c b/fs/xfs/xfs_inode.c
index b7352bc4c815..7289325aa5c7 100644
--- a/fs/xfs/xfs_inode.c
+++ b/fs/xfs/xfs_inode.c
@@ -775,6 +775,7 @@  xfs_init_new_inode(
 	prid_t			prid,
 	struct xfs_inode	**ipp)
 {
+	struct inode		*dir = pip ? VFS_I(pip) : NULL;
 	struct xfs_mount	*mp = tp->t_mountp;
 	struct xfs_inode	*ip;
 	unsigned int		flags;
@@ -804,18 +805,17 @@  xfs_init_new_inode(
 
 	ASSERT(ip != NULL);
 	inode = VFS_I(ip);
-	inode->i_mode = mode;
 	set_nlink(inode, nlink);
-	inode->i_uid = current_fsuid();
 	inode->i_rdev = rdev;
 	ip->i_d.di_projid = prid;
 
-	if (pip && XFS_INHERIT_GID(pip)) {
-		inode->i_gid = VFS_I(pip)->i_gid;
-		if ((VFS_I(pip)->i_mode & S_ISGID) && S_ISDIR(mode))
-			inode->i_mode |= S_ISGID;
+	if (dir && !(dir->i_mode & S_ISGID) &&
+	    (mp->m_flags & XFS_MOUNT_GRPID)) {
+		inode->i_uid = current_fsuid();
+		inode->i_gid = dir->i_gid;
+		inode->i_mode = mode;
 	} else {
-		inode->i_gid = current_fsgid();
+		inode_init_owner(inode, dir, mode);
 	}
 
 	/*