diff mbox series

[3/7] rtc: cros-ec: Detect and report supported alarm window size

Message ID 20230816133936.2150294-4-linux@roeck-us.net
State Superseded
Headers show
Series rtc: Add support for limited alarm timer offsets | expand

Commit Message

Guenter Roeck Aug. 16, 2023, 1:39 p.m. UTC
The RTC on some older Chromebooks can only handle alarms less than
24 hours in the future. The only way to find out is to try to set
an alarm further in the future. If that fails, assume that the RTC
connected to the EC can only handle less than 24 hours of alarm
window, and report that value to the RTC core.

After that change, it is no longer necessary to limit the alarm time
when setting it. Report any excessive alarms to the caller instead.

Cc: Brian Norris <briannorris@chromium.org>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
---
 drivers/rtc/rtc-cros-ec.c | 38 +++++++++++++++++++++++---------------
 1 file changed, 23 insertions(+), 15 deletions(-)
diff mbox series

Patch

diff --git a/drivers/rtc/rtc-cros-ec.c b/drivers/rtc/rtc-cros-ec.c
index 998ab8606f0b..a257a24e8223 100644
--- a/drivers/rtc/rtc-cros-ec.c
+++ b/drivers/rtc/rtc-cros-ec.c
@@ -182,21 +182,15 @@  static int cros_ec_rtc_set_alarm(struct device *dev, struct rtc_wkalrm *alrm)
 
 	ret = cros_ec_rtc_set(cros_ec, EC_CMD_RTC_SET_ALARM, alarm_offset);
 	if (ret < 0) {
-		if (ret == -EINVAL && alarm_offset >= SECS_PER_DAY) {
-			/*
-			 * RTC chips on some older Chromebooks can only handle
-			 * alarms up to 24h in the future. Try to set an alarm
-			 * below that limit to avoid suspend failures.
-			 */
-			ret = cros_ec_rtc_set(cros_ec, EC_CMD_RTC_SET_ALARM,
-					      SECS_PER_DAY - 1);
-		}
-
-		if (ret < 0) {
-			dev_err(dev, "error setting alarm in %u seconds: %d\n",
-				alarm_offset, ret);
-			return ret;
-		}
+		dev_err(dev, "error setting alarm in %u seconds: %d\n",
+			alarm_offset, ret);
+		/*
+		 * The EC code returns -EINVAL if the alarm time is too
+		 * far in the future. Convert it to the expected error code.
+		 */
+		if (ret == -EINVAL)
+			ret = -ERANGE;
+		return ret;
 	}
 
 	return 0;
@@ -355,6 +349,20 @@  static int cros_ec_rtc_probe(struct platform_device *pdev)
 	cros_ec_rtc->rtc->ops = &cros_ec_rtc_ops;
 	cros_ec_rtc->rtc->range_max = U32_MAX;
 
+	/*
+	 * The RTC on some older Chromebooks can only handle alarms less than
+	 * 24 hours in the future. The only way to find out is to try to set an
+	 * alarm further in the future. If that fails, assume that the RTC
+	 * connected to the EC can only handle less than 24 hours of alarm
+	 * window.
+	 */
+	ret = cros_ec_rtc_set(cros_ec, EC_CMD_RTC_SET_ALARM, SECS_PER_DAY * 2);
+	if (ret == -EINVAL)
+		cros_ec_rtc->rtc->range_max_offset = SECS_PER_DAY - 1;
+
+	(void)cros_ec_rtc_set(cros_ec, EC_CMD_RTC_SET_ALARM,
+			      EC_RTC_ALARM_CLEAR);
+
 	ret = devm_rtc_register_device(cros_ec_rtc->rtc);
 	if (ret)
 		return ret;