Message ID | 20230403-da9063-disable-unused-v2-3-2f1bd2a2434a@skidata.com |
---|---|
State | Not Applicable, archived |
Headers | show |
Series | regulator: da9063: disable unused voltage monitors | expand |
Context | Check | Description |
---|---|---|
robh/checkpatch | success | |
robh/patch-applied | success | |
robh/dtbs-check | warning | build log |
robh/dt-meta-schema | success |
On 05/04/2023 07:29, Benjamin Bara wrote: > From: Benjamin Bara <benjamin.bara@skidata.com> > > Document that the da9063 only provides UVP *and* OVP in one, and > therefore requires both configured. Add an example for clarification. > > Signed-off-by: Benjamin Bara <benjamin.bara@skidata.com> Acked-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> Best regards, Krzysztof
diff --git a/Documentation/devicetree/bindings/mfd/dlg,da9063.yaml b/Documentation/devicetree/bindings/mfd/dlg,da9063.yaml index e8e74e91070c..e9d5ab418dd2 100644 --- a/Documentation/devicetree/bindings/mfd/dlg,da9063.yaml +++ b/Documentation/devicetree/bindings/mfd/dlg,da9063.yaml @@ -12,6 +12,10 @@ maintainers: description: | For device-tree bindings of other sub-modules refer to the binding documents under the respective sub-system directories. + Using regulator-uv-X-microvolt and regulator-ov-X-microvolt requires special + handling: First, when GP_FB2 is used, it must be ensured that there is no + moment where all voltage monitors are disabled. Next, as da9063 only supports + UV *and* OV monitoring, both must be set. properties: compatible: @@ -121,11 +125,19 @@ examples: regulator-max-microamp = <2000000>; regulator-boot-on; }; + ldo6 { + /* UNUSED */ + regulator-name = "LDO_6"; + regulator-uv-protection-microvolt = <0>; + regulator-ov-protection-microvolt = <0>; + }; ldo11 { regulator-name = "LDO_11"; regulator-min-microvolt = <900000>; - regulator-max-microvolt = <3600000>; - regulator-boot-on; + regulator-max-microvolt = <900000>; + regulator-uv-protection-microvolt = <1>; + regulator-ov-protection-microvolt = <1>; + regulator-always-on; }; }; };