Łukasz Majewski Dec. 22, 2014, 4:27 p.m. UTC
Several new properties to allow PWM fan working as a cooling device have been
combined into this single commit.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
---
Changes for v2:
- Rename cooling-pwm-values to cooling-levels
- Remove default-pulse-width property and stick to default hwmon policy
---
 .../devicetree/bindings/hwmon/pwm-fan.txt          | 23 ++++++++++++++++++++++
 1 file changed, 23 insertions(+)

Comments

Eduardo Valentin Jan. 2, 2015, 6:51 p.m. UTC | #1
On Mon, Dec 22, 2014 at 05:27:43PM +0100, Lukasz Majewski wrote:
> Several new properties to allow PWM fan working as a cooling device have been
> combined into this single commit.
> 

Patch prefix should look something like 'dt-bindings: ...', or better
'Documentation: devicetree: ...', or 'Documentation: bindings: ...'

> Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
> ---
> Changes for v2:
> - Rename cooling-pwm-values to cooling-levels
> - Remove default-pulse-width property and stick to default hwmon policy
> ---
>  .../devicetree/bindings/hwmon/pwm-fan.txt          | 23 ++++++++++++++++++++++
>  1 file changed, 23 insertions(+)
> 
> diff --git a/Documentation/devicetree/bindings/hwmon/pwm-fan.txt b/Documentation/devicetree/bindings/hwmon/pwm-fan.txt
> index 610757c..001446a 100644
> --- a/Documentation/devicetree/bindings/hwmon/pwm-fan.txt
> +++ b/Documentation/devicetree/bindings/hwmon/pwm-fan.txt
> @@ -3,10 +3,33 @@ Bindings for a fan connected to the PWM lines
>  Required properties:
>  - compatible	: "pwm-fan"
>  - pwms		: the PWM that is used to control the PWM fan
> +- cooling-levels      : PWM duty cycle values in a range from 0 to 255
> +			which correspond to thermal cooling states
> +
> +Thorough description of the following bindings:
> +		cooling-min-state = <0>;
> +		cooling-max-state = <3>;
> +		#cooling-cells = <2>;
> +		thermal-zone {
> +			cpu_thermal: cpu-thermal {
> +			cooling-maps {
> +				map0 {
> +				     trip = <&cpu_alert1>;
> +				     cooling-device = <&fan0 0 1>;
> +				};
> +			};
> +		};
> +
> +for PWM FAN used as cooling device can be found at:
> +./Documentation/devicetree/bindings/thermal/thermal.txt
>  
>  Example:
>  	pwm-fan {
>  		compatible = "pwm-fan";
>  		status = "okay";
>  		pwms = <&pwm 0 10000 0>;
> +		cooling-min-state = <0>;
> +		cooling-max-state = <3>;
> +		#cooling-cells = <2>;
> +		cooling-levels = <0 102 170 255>;
>  	};
> -- 
> 2.0.0.rc2
>
diff mbox

Patch

diff --git a/Documentation/devicetree/bindings/hwmon/pwm-fan.txt b/Documentation/devicetree/bindings/hwmon/pwm-fan.txt
index 610757c..001446a 100644
--- a/Documentation/devicetree/bindings/hwmon/pwm-fan.txt
+++ b/Documentation/devicetree/bindings/hwmon/pwm-fan.txt
@@ -3,10 +3,33 @@  Bindings for a fan connected to the PWM lines
 Required properties:
 - compatible	: "pwm-fan"
 - pwms		: the PWM that is used to control the PWM fan
+- cooling-levels      : PWM duty cycle values in a range from 0 to 255
+			which correspond to thermal cooling states
+
+Thorough description of the following bindings:
+		cooling-min-state = <0>;
+		cooling-max-state = <3>;
+		#cooling-cells = <2>;
+		thermal-zone {
+			cpu_thermal: cpu-thermal {
+			cooling-maps {
+				map0 {
+				     trip = <&cpu_alert1>;
+				     cooling-device = <&fan0 0 1>;
+				};
+			};
+		};
+
+for PWM FAN used as cooling device can be found at:
+./Documentation/devicetree/bindings/thermal/thermal.txt
 
 Example:
 	pwm-fan {
 		compatible = "pwm-fan";
 		status = "okay";
 		pwms = <&pwm 0 10000 0>;
+		cooling-min-state = <0>;
+		cooling-max-state = <3>;
+		#cooling-cells = <2>;
+		cooling-levels = <0 102 170 255>;
 	};