@@ -72,9 +72,9 @@ or from a distribution tar ball.
directories, etc. For example,
% ./configure CC=./build-aux/cccl LD="`which link`" \
- LIBS="-lws2_32 -liphlpapi" --prefix="C:/openvswitch/usr" \
- --localstatedir="C:/openvswitch/var" --sysconfdir="C:/openvswitch/etc" \
- --with-pthread="C:/pthread"
+ LIBS="-lws2_32 -liphlpapi -lwbemuuid -lole32 -loleaut32" \
+ --prefix="C:/openvswitch/usr" --localstatedir="C:/openvswitch/var" \
+ --sysconfdir="C:/openvswitch/etc" --with-pthread="C:/pthread"
By default, the above enables compiler optimization for fast code.
For default compiler optimization, pass the "--with-debug" configure
@@ -125,9 +125,10 @@ Note down the directory where OpenSSL is installed (e.g.: C:/OpenSSL-Win32).
For example,
% ./configure CC=./build-aux/cccl LD="`which link`" \
- LIBS="-lws2_32 -liphlpapi" --prefix="C:/openvswitch/usr" \
- --localstatedir="C:/openvswitch/var" --sysconfdir="C:/openvswitch/etc" \
- --with-pthread="C:/pthread" --enable-ssl --with-openssl="C:/OpenSSL-Win32"
+ LIBS="-lws2_32 -liphlpapi -lwbemuuid -lole32 -loleaut32" \
+ --prefix="C:/openvswitch/usr" --localstatedir="C:/openvswitch/var" \
+ --sysconfdir="C:/openvswitch/etc" --with-pthread="C:/pthread" \
+ --enable-ssl --with-openssl="C:/OpenSSL-Win32"
* Run make for the ported executables.
@@ -142,10 +143,11 @@ level 'make' will invoke building the kernel datapath, if the
For example,
% ./configure CC=./build-aux/cccl LD="`which link`" \
- LIBS="-lws2_32 -liphlpapi" --prefix="C:/openvswitch/usr" \
- --localstatedir="C:/openvswitch/var" --sysconfdir="C:/openvswitch/etc" \
- --with-pthread="C:/pthread" --enable-ssl \
- --with-openssl="C:/OpenSSL-Win32" --with-vstudiotarget="<target type>"
+ LIBS="-lws2_32 -liphlpapi -lwbemuuid -lole32 -loleaut32" \
+ --prefix="C:/openvswitch/usr" --localstatedir="C:/openvswitch/var" \
+ --sysconfdir="C:/openvswitch/etc" --with-pthread="C:/pthread" \
+ --enable-ssl --with-openssl="C:/OpenSSL-Win32" \
+ --with-vstudiotarget="<target type>"
Possible values for "<target type>" are:
"Debug" and "Release"
@@ -186,8 +188,7 @@ to work (covered later).
The command to create a new switch named 'OVS-Extended-Switch' using a physical
NIC named 'Ethernet 1' is:
- % New-VMSwitch "OVS-Extended-Switch" -AllowManagementOS $true \
- -NetAdapterName "Ethernet 1"
+ % New-VMSwitch "OVS-Extended-Switch" -NetAdapterName "Ethernet 1"
Note: you can obtain the list of physical NICs on the host using
'Get-NetAdapter' command.
@@ -278,23 +279,20 @@ connected to the Hyper-V switch. I.e. let us suppose we created the Hyper-V
virtual switch on top of the adapter named 'Ethernet0'. In OVS for Hyper-V, we
use that name('Ethernet0') as a special name to refer to that adapter.
-Note: Currently, we assume that the Hyper-V switch on which OVS extension is
-enabled has a single physical NIC connected to it.
-
-Internal port is the virtual adapter created on the Hyper-V switch using the
-'AllowManagementOS' setting. This has already been setup while creating the
-switch using the instructions above. In OVS for Hyper-V, we use a the name of
-that specific adapter as a special name to refer to that adapter. By default it
-is created under the following rule "vEthernet (<name of the switch>)".
+Internal ports are the virtual adapters created on the Hyper-V switch using the
+ovs-vsctl add-br <bridge> command. By default they are created under the
+following rule "<name of bridge>" and the adapters are disabled. One needs to
+enable them and set the corresponding values to it to make them IP-able.
As a whole example, if we issue the following in a powershell console:
-PS C:\package\binaries> Get-NetAdapter | select Name,MacAddress,InterfaceDescription
+PS C:\package\binaries> Get-NetAdapter | select Name,InterfaceDescription
-Name MacAddress InterfaceDescription
----- ---------- --------------------
-Ethernet1 00-0C-29-94-05-65 Intel(R) PRO/1000 MT Network Connection
-vEthernet (external) 00-0C-29-94-05-5B Hyper-V Virtual Ethernet Adapter #2
-Ethernet0 00-0C-29-94-05-5B Intel(R) PRO/1000 MT Network Connection #2
+Name InterfaceDescription
+---- --------------------
+Ethernet1 Intel(R) PRO/1000 MT Network Connection
+br-pif Hyper-V Virtual Ethernet Adapter #2
+Ethernet0 Intel(R) PRO/1000 MT Network Connection #2
+br-int Hyper-V Virtual Ethernet Adapter #3
PS C:\package\binaries> Get-VMSwitch
@@ -302,13 +300,11 @@ Name SwitchType NetAdapterInterfaceDescription
---- ---------- ------------------------------
external External Intel(R) PRO/1000 MT Network Connection #2
-
-We can see that we have a switch(external) created upon adapter name 'Ethernet0'
-with an internal port under name 'vEthernet (external)'. Thus resulting into the
-following ovs-vsctl commands
+We can see that we have a switch(external) created upon adapter name
+'Ethernet0' with the internal ports under name 'br-pif' and 'br-int'. Thus
+resulting into the following ovs-vsctl commands
% ovs-vsctl add-port br-pif Ethernet0
- % ovs-vsctl add-port br-pif "vEthernet (external)"
* Dumping the ports should show the additional ports that were just added.
Sample output shows up as follows:
@@ -317,18 +313,17 @@ following ovs-vsctl commands
system@ovs-system:
lookups: hit:0 missed:0 lost:0
flows: 0
- port 4: vEthernet (external) (internal) <<< 'AllowManagementOS'
- adapter on
- Hyper-V switch
- port 2: br-pif (internal)
- port 1: br-int (internal)
+ port 2: br-pif (internal) <<< internal port
+ adapter on
+ Hyper-V switch
+ port 1: br-int (internal) <<< internal port
+ adapter on
+ Hyper-V switch
port 3: Ethernet0 <<< Physical NIC
% ovs-vsctl show
a56ec7b5-5b1f-49ec-a795-79f6eb63228b
Bridge br-pif
- Port "vEthernet (external)"
- Interface "vEthernet (external)"
Port br-pif
Interface br-pif
type: internal
@@ -374,8 +369,7 @@ with OVS extension enabled.
system@ovs-system:
lookups: hit:0 missed:0 lost:0
flows: 0
- port 4: vEthernet (external) (internal)
- port 5: ovs-port-a
+ port 4: ovs-port-a
port 2: br-pif (internal)
port 1: br-int (internal
port 3: Ethernet0
@@ -383,8 +377,6 @@ with OVS extension enabled.
% ovs-vsctl show
4cd86499-74df-48bd-a64d-8d115b12a9f2
Bridge br-pif
- Port "vEthernet (external)"
- Interface "vEthernet (external)"
Port "Ethernet0"
Interface "Ethernet0"
Port br-pif
@@ -397,6 +389,73 @@ with OVS extension enabled.
Port "ovs-port-a"
Interface "ovs-port-a"
+Steps to add multiple NICs to be managed by OVS
+-----------------------------------------------
+
+To leverage support of multiple NICs into OVS, we will be using the MSFT
+cmdlets for forwarding team extension. More documentation can be found
+under:
+https://technet.microsoft.com/en-us/library/jj553812%28v=wps.630%29.aspx
+
+Eg:
+We will set up a switch team combined from 'Ethernet0 2' and 'Ethernet1 2'
+named external.
+
+% Get-NetAdapter
+
+Name InterfaceDescription
+---- --------------------
+br-int Hyper-V Virtual Ethernet Adapter #3
+br-pif Hyper-V Virtual Ethernet Adapter #2
+Ethernet3 2 Intel(R) 82574L Gigabit Network Co...#3
+Ethernet2 2 Intel(R) 82574L Gigabit Network Co...#4
+Ethernet1 2 Intel(R) 82574L Gigabit Network Co...#2
+Ethernet0 2 Intel(R) 82574L Gigabit Network Conn...
+
+% New-NetSwitchTeam -Name external -TeamMembers "Ethernet0 2","Ethernet1 2"
+% Get-NetSwitchTeam
+Name : external
+Members : {Ethernet1 2, Ethernet0 2}
+
+This will result in a new adapter bound to the host called 'external'
+
+% Get-NetAdapter
+
+Name InterfaceDescription
+---- --------------------
+br-test Hyper-V Virtual Ethernet Adapter #4
+br-pif Hyper-V Virtual Ethernet Adapter #2
+external Microsoft Network Adapter Multiplexo...
+Ethernet3 2 Intel(R) 82574L Gigabit Network Co...#3
+Ethernet2 2 Intel(R) 82574L Gigabit Network Co...#4
+Ethernet1 2 Intel(R) 82574L Gigabit Network Co...#2
+Ethernet0 2 Intel(R) 82574L Gigabit Network Conn...
+
+Next we will set up the Hyper-V VMSwitch on the new adapter 'external'
+
+%New-VMSwitch -Name external -NetAdapterName external -AllowManagementOS $false
+
+Under OVS, the adapters added to the team, 'Ethernet0 2' and 'Ethernet1 2', can
+be added either under a bond device or separately.
+
+In our example here is how the bridges look with the NICs being separated under
+different bridges:
+
+% ovs-vsctl show
+6cd9481b-c249-4ee3-8692-97b399dd29d8
+ Bridge br-test
+ Port br-test
+ Interface br-test
+ type: internal
+ Port "Ethernet1 2"
+ Interface "Ethernet1 2"
+ Bridge br-pif
+ Port "Ethernet0 2"
+ Interface "Ethernet0 2"
+ Port br-pif
+ Interface br-pif
+ type: internal
+
Steps to configure patch ports and switch VLAN tagging
------------------------------------------------------