@@ -1447,7 +1447,6 @@ static void p8_i2c_init_one(struct dt_node *i2cm, enum p8_i2c_master_type type)
struct p8_i2c_master *master;
struct list_head *chip_list;
uint64_t ex_stat, default_timeout;
- static bool irq_printed;
int64_t rc;
master = zalloc(sizeof(*master));
@@ -1496,8 +1495,11 @@ static void p8_i2c_init_one(struct dt_node *i2cm, enum p8_i2c_master_type type)
init_timer(&master->recovery, p8_i2c_recover, master);
init_timer(&master->sensor_cache, p8_i2c_enable_scache, master);
- prlog(PR_INFO, "I2C: Chip %08x Eng. %d Clock %d Mhz\n",
- master->chip_id, master->engine_id, lb_freq / 1000000);
+ master->irq_ok = p8_i2c_has_irqs(master);
+
+ prlog(PR_INFO, "I2C: Chip %08x Eng. %d Clock %d Mhz %s\n",
+ master->chip_id, master->engine_id, lb_freq / 1000000,
+ master->irq_ok ? "" : "(no interrupt)");
/* Disable OCC cache during inits */
if (master->type == I2C_CENTAUR) {
@@ -1526,14 +1528,6 @@ static void p8_i2c_init_one(struct dt_node *i2cm, enum p8_i2c_master_type type)
list_head_init(&master->req_list);
list_head_init(&master->ports);
- /* Check if interrupt is usable */
- master->irq_ok = p8_i2c_has_irqs(master);
- if (!irq_printed) {
- irq_printed = true;
- prlog(PR_INFO, "I2C: Interrupts %sfunctional\n",
- master->irq_ok ? "" : "non-");
- }
-
/* Re-enable the sensor cache, we aren't touching HW anymore */
if (master->type == I2C_CENTAUR)
centaur_enable_sensor_cache(master->chip_id);
Whether I2C interrupts work or not depends on the type of master. Currently we print a single message to indicate whether IRQs work or not, but this will be wrong if we have I2C interrupts on the host and we happen to probe a Centaur I2C master first. Fix this by adding a message to the per-master print indicating whether the master has an interrupt or not. Signed-off-by: Oliver O'Halloran <oohall@gmail.com> --- hw/p8-i2c.c | 16 +++++----------- 1 file changed, 5 insertions(+), 11 deletions(-)