diff mbox series

[PULL,36/39] hw/intc/arm_gicv3_its: In MAPC with V=0, don't check rdbase field

Message ID 20220208113948.3217356-37-peter.maydell@linaro.org
State New
Headers show
Series [PULL,01/39] target/arm: Fix sve_zcr_len_for_el for VHE mode running | expand

Commit Message

Peter Maydell Feb. 8, 2022, 11:39 a.m. UTC
In the MAPC command, if V=0 this is a request to delete a collection
table entry and the rdbase field of the command packet will not be
used.  In particular, the specification says that the "UNPREDICTABLE
if rdbase is not valid" only applies for V=1.

We were doing a check-and-log-guest-error on rdbase regardless of
whether the V bit was set, and also (harmlessly but confusingly)
storing the contents of the rdbase field into the updated collection
table entry.  Update the code so that if V=0 we don't check or use
the rdbase field value.

Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
Reviewed-by: Richard Henderson <richard.henderson@linaro.org>
Message-id: 20220201193207.2771604-12-peter.maydell@linaro.org
---
 hw/intc/arm_gicv3_its.c | 24 ++++++++++++------------
 1 file changed, 12 insertions(+), 12 deletions(-)
diff mbox series

Patch

diff --git a/hw/intc/arm_gicv3_its.c b/hw/intc/arm_gicv3_its.c
index 9735d609df2..069991f7f36 100644
--- a/hw/intc/arm_gicv3_its.c
+++ b/hw/intc/arm_gicv3_its.c
@@ -468,21 +468,21 @@  static ItsCmdResult process_mapc(GICv3ITSState *s, const uint64_t *cmdpkt)
     CTEntry cte;
 
     icid = cmdpkt[2] & ICID_MASK;
-
-    cte.rdbase = (cmdpkt[2] & R_MAPC_RDBASE_MASK) >> R_MAPC_RDBASE_SHIFT;
-    cte.rdbase &= RDBASE_PROCNUM_MASK;
-
     cte.valid = cmdpkt[2] & CMD_FIELD_VALID_MASK;
+    if (cte.valid) {
+        cte.rdbase = (cmdpkt[2] & R_MAPC_RDBASE_MASK) >> R_MAPC_RDBASE_SHIFT;
+        cte.rdbase &= RDBASE_PROCNUM_MASK;
+    } else {
+        cte.rdbase = 0;
+    }
 
-    if ((icid >= s->ct.num_entries) || (cte.rdbase >= s->gicv3->num_cpu)) {
+    if (icid >= s->ct.num_entries) {
+        qemu_log_mask(LOG_GUEST_ERROR, "ITS MAPC: invalid ICID 0x%d", icid);
+        return CMD_CONTINUE;
+    }
+    if (cte.valid && cte.rdbase >= s->gicv3->num_cpu) {
         qemu_log_mask(LOG_GUEST_ERROR,
-                      "ITS MAPC: invalid collection table attributes "
-                      "icid %d rdbase %u\n",  icid, cte.rdbase);
-        /*
-         * in this implementation, in case of error
-         * we ignore this command and move onto the next
-         * command in the queue
-         */
+                      "ITS MAPC: invalid RDBASE %u ", cte.rdbase);
         return CMD_CONTINUE;
     }