On Mon, Oct 15, 2018 at 04:14:45PM +0200, Max Reitz wrote: > When closing a connection, make the nbd-fault-injector flush the socket. > Without this, the output is a bit unreliable with Python 3. > > Signed-off-by: Max Reitz <mreitz@redhat.com> Reviewed-by: Eduardo Habkost <ehabkost@redhat.com>
On 10/15/18 10:14 AM, Max Reitz wrote: > When closing a connection, make the nbd-fault-injector flush the socket. > Without this, the output is a bit unreliable with Python 3. > > Signed-off-by: Max Reitz <mreitz@redhat.com> Reviewed-by: Cleber Rosa <crosa@redhat.com>
On 10/15/18 9:14 AM, Max Reitz wrote: > When closing a connection, make the nbd-fault-injector flush the socket. > Without this, the output is a bit unreliable with Python 3. > > Signed-off-by: Max Reitz <mreitz@redhat.com> > --- > tests/qemu-iotests/083.out | 9 +++++++++ > tests/qemu-iotests/nbd-fault-injector.py | 1 + > 2 files changed, 10 insertions(+) I already had a complaint that the error message in 083.out should NOT be printing a message (whether the server is python 2 and auto-flushes, or python 3 and needs an explicit flush, the message itself is pointless, and the test is racy as a result). We may need to revisit this patch when that thread is resolved. https://lists.gnu.org/archive/html/qemu-devel/2018-08/msg01041.html That said, I'm not opposed to this patch, if it gets iotests to be more useful in the meantime. > > diff --git a/tests/qemu-iotests/083.out b/tests/qemu-iotests/083.out > index be6079d27e..f9af8bb691 100644 > --- a/tests/qemu-iotests/083.out > +++ b/tests/qemu-iotests/083.out > @@ -41,6 +41,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo > > === Check disconnect after neg2 === > > +Unable to read from socket: Connection reset by peer > Connection closed > read failed: Input/output error > > @@ -54,6 +55,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo > > === Check disconnect before request === > > +Unable to read from socket: Connection reset by peer > Connection closed > read failed: Input/output error > > @@ -116,6 +118,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/ > > === Check disconnect after neg-classic === > > +Unable to read from socket: Connection reset by peer > Connection closed > read failed: Input/output error > > @@ -161,6 +164,8 @@ can't open device nbd+unix:///foo?socket=TEST_DIR/nbd.sock > > === Check disconnect after neg2 === > > +Unable to read from socket: Connection reset by peer > +Connection closed > read failed: Input/output error > > === Check disconnect 8 neg2 === > @@ -173,6 +178,8 @@ can't open device nbd+unix:///foo?socket=TEST_DIR/nbd.sock > > === Check disconnect before request === > > +Unable to read from socket: Connection reset by peer > +Connection closed > read failed: Input/output error > > === Check disconnect after request === > @@ -234,6 +241,8 @@ can't open device nbd+unix:///?socket=TEST_DIR/nbd.sock > > === Check disconnect after neg-classic === > > +Unable to read from socket: Connection reset by peer > +Connection closed > read failed: Input/output error > > *** done > diff --git a/tests/qemu-iotests/nbd-fault-injector.py b/tests/qemu-iotests/nbd-fault-injector.py > index f9193c0fae..439a090eb6 100755 > --- a/tests/qemu-iotests/nbd-fault-injector.py > +++ b/tests/qemu-iotests/nbd-fault-injector.py > @@ -112,6 +112,7 @@ class FaultInjectionSocket(object): > if rule.match(event, io): > if rule.when == 0 or bufsize is None: > print('Closing connection on rule match %s' % rule.name) > + self.sock.flush() > sys.exit(0) > if rule.when != -1: > return rule.when >
On 16.10.18 20:07, Eric Blake wrote: > On 10/15/18 9:14 AM, Max Reitz wrote: >> When closing a connection, make the nbd-fault-injector flush the socket. >> Without this, the output is a bit unreliable with Python 3. >> >> Signed-off-by: Max Reitz <mreitz@redhat.com> >> --- >> tests/qemu-iotests/083.out | 9 +++++++++ >> tests/qemu-iotests/nbd-fault-injector.py | 1 + >> 2 files changed, 10 insertions(+) > > I already had a complaint that the error message in 083.out should NOT > be printing a message You mean the NBD server itself, right? > (whether the server is python 2 and auto-flushes, > or python 3 and needs an explicit flush, the message itself is > pointless, and the test is racy as a result). We may need to revisit > this patch when that thread is resolved. > > https://lists.gnu.org/archive/html/qemu-devel/2018-08/msg01041.html Well, it's not like the flush hurts either way. :-) Max > That said, I'm not opposed to this patch, if it gets iotests to be more > useful in the meantime. > >> >> diff --git a/tests/qemu-iotests/083.out b/tests/qemu-iotests/083.out >> index be6079d27e..f9af8bb691 100644 >> --- a/tests/qemu-iotests/083.out >> +++ b/tests/qemu-iotests/083.out >> @@ -41,6 +41,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo >> === Check disconnect after neg2 === >> +Unable to read from socket: Connection reset by peer >> Connection closed >> read failed: Input/output error >> @@ -54,6 +55,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo >> === Check disconnect before request === >> +Unable to read from socket: Connection reset by peer >> Connection closed >> read failed: Input/output error >> @@ -116,6 +118,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/ >> === Check disconnect after neg-classic === >> +Unable to read from socket: Connection reset by peer >> Connection closed >> read failed: Input/output error >> @@ -161,6 +164,8 @@ can't open device >> nbd+unix:///foo?socket=TEST_DIR/nbd.sock >> === Check disconnect after neg2 === >> +Unable to read from socket: Connection reset by peer >> +Connection closed >> read failed: Input/output error >> === Check disconnect 8 neg2 === >> @@ -173,6 +178,8 @@ can't open device >> nbd+unix:///foo?socket=TEST_DIR/nbd.sock >> === Check disconnect before request === >> +Unable to read from socket: Connection reset by peer >> +Connection closed >> read failed: Input/output error >> === Check disconnect after request === >> @@ -234,6 +241,8 @@ can't open device >> nbd+unix:///?socket=TEST_DIR/nbd.sock >> === Check disconnect after neg-classic === >> +Unable to read from socket: Connection reset by peer >> +Connection closed >> read failed: Input/output error >> *** done >> diff --git a/tests/qemu-iotests/nbd-fault-injector.py >> b/tests/qemu-iotests/nbd-fault-injector.py >> index f9193c0fae..439a090eb6 100755 >> --- a/tests/qemu-iotests/nbd-fault-injector.py >> +++ b/tests/qemu-iotests/nbd-fault-injector.py >> @@ -112,6 +112,7 @@ class FaultInjectionSocket(object): >> if rule.match(event, io): >> if rule.when == 0 or bufsize is None: >> print('Closing connection on rule match %s' % >> rule.name) >> + self.sock.flush() >> sys.exit(0) >> if rule.when != -1: >> return rule.when >> >
On 10/19/18 4:48 AM, Max Reitz wrote: > On 16.10.18 20:07, Eric Blake wrote: >> On 10/15/18 9:14 AM, Max Reitz wrote: >>> When closing a connection, make the nbd-fault-injector flush the socket. >>> Without this, the output is a bit unreliable with Python 3. >>> >>> Signed-off-by: Max Reitz <mreitz@redhat.com> >>> --- >>> tests/qemu-iotests/083.out | 9 +++++++++ >>> tests/qemu-iotests/nbd-fault-injector.py | 1 + >>> 2 files changed, 10 insertions(+) >> >> I already had a complaint that the error message in 083.out should NOT >> be printing a message > > You mean the NBD server itself, right? Yes, the NBD server should not be printing the redundant error messages that 083.out exposes. > >> (whether the server is python 2 and auto-flushes, >> or python 3 and needs an explicit flush, the message itself is >> pointless, and the test is racy as a result). We may need to revisit >> this patch when that thread is resolved. >> >> https://lists.gnu.org/archive/html/qemu-devel/2018-08/msg01041.html > > Well, it's not like the flush hurts either way. :-) True. On that grounds: Reviewed-by: Eric Blake <eblake@redhat.com>
diff --git a/tests/qemu-iotests/083.out b/tests/qemu-iotests/083.out index be6079d27e..f9af8bb691 100644 --- a/tests/qemu-iotests/083.out +++ b/tests/qemu-iotests/083.out @@ -41,6 +41,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo === Check disconnect after neg2 === +Unable to read from socket: Connection reset by peer Connection closed read failed: Input/output error @@ -54,6 +55,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/foo === Check disconnect before request === +Unable to read from socket: Connection reset by peer Connection closed read failed: Input/output error @@ -116,6 +118,7 @@ can't open device nbd+tcp://127.0.0.1:PORT/ === Check disconnect after neg-classic === +Unable to read from socket: Connection reset by peer Connection closed read failed: Input/output error @@ -161,6 +164,8 @@ can't open device nbd+unix:///foo?socket=TEST_DIR/nbd.sock === Check disconnect after neg2 === +Unable to read from socket: Connection reset by peer +Connection closed read failed: Input/output error === Check disconnect 8 neg2 === @@ -173,6 +178,8 @@ can't open device nbd+unix:///foo?socket=TEST_DIR/nbd.sock === Check disconnect before request === +Unable to read from socket: Connection reset by peer +Connection closed read failed: Input/output error === Check disconnect after request === @@ -234,6 +241,8 @@ can't open device nbd+unix:///?socket=TEST_DIR/nbd.sock === Check disconnect after neg-classic === +Unable to read from socket: Connection reset by peer +Connection closed read failed: Input/output error *** done diff --git a/tests/qemu-iotests/nbd-fault-injector.py b/tests/qemu-iotests/nbd-fault-injector.py index f9193c0fae..439a090eb6 100755 --- a/tests/qemu-iotests/nbd-fault-injector.py +++ b/tests/qemu-iotests/nbd-fault-injector.py @@ -112,6 +112,7 @@ class FaultInjectionSocket(object): if rule.match(event, io): if rule.when == 0 or bufsize is None: print('Closing connection on rule match %s' % rule.name) + self.sock.flush() sys.exit(0) if rule.when != -1: return rule.when
When closing a connection, make the nbd-fault-injector flush the socket. Without this, the output is a bit unreliable with Python 3. Signed-off-by: Max Reitz <mreitz@redhat.com> --- tests/qemu-iotests/083.out | 9 +++++++++ tests/qemu-iotests/nbd-fault-injector.py | 1 + 2 files changed, 10 insertions(+)