From patchwork Tue Apr 12 14:59:25 2016 Content-Type: text/plain; charset="utf-8" MIME-Version: 1.0 Content-Transfer-Encoding: 7bit X-Patchwork-Submitter: Max X-Patchwork-Id: 609439 Return-Path: X-Original-To: incoming@patchwork.ozlabs.org Delivered-To: patchwork-incoming@bilbo.ozlabs.org Received: from lists.osmocom.org (lists.osmocom.org [IPv6:2a01:4f8:191:444b::2:7]) by ozlabs.org (Postfix) with ESMTP id 3qkqq35k9jz9s36 for ; Wed, 13 Apr 2016 00:59:59 +1000 (AEST) Received: from lists.osmocom.org (lists.osmocom.org [144.76.43.76]) by lists.osmocom.org (Postfix) with ESMTP id 1BA911D998; Tue, 12 Apr 2016 14:59:58 +0000 (UTC) X-Original-To: openbsc@lists.osmocom.org Delivered-To: openbsc@lists.osmocom.org Received: from mail.sysmocom.de (mail.sysmocom.de [IPv6:2a01:4f8:191:444c::2:4]) by lists.osmocom.org (Postfix) with ESMTP id 99E061D988 for ; Tue, 12 Apr 2016 14:59:56 +0000 (UTC) Received: from mail.sysmocom.de (mail.sysmocom.de [144.76.43.93]) by mail.sysmocom.de (Postfix) with ESMTP id 422861A7FF0; Tue, 12 Apr 2016 14:59:26 +0000 (UTC) Received: from pbell.local (ip5b418565.dynamic.kabel-deutschland.de [91.65.133.101]) by mail.sysmocom.de (Postfix) with ESMTPSA id E96F91A7FEF; Tue, 12 Apr 2016 14:59:25 +0000 (UTC) From: msuraev@sysmocom.de To: openbsc@lists.osmocom.org Subject: [PATCH] NAT: move BSC config into separate file Date: Tue, 12 Apr 2016 16:59:25 +0200 Message-Id: <1460473165-1700-1-git-send-email-msuraev@sysmocom.de> X-Mailer: git-send-email 2.8.1 X-Virus-Scanned: ClamAV using ClamSMTP X-BeenThere: openbsc@lists.osmocom.org X-Mailman-Version: 2.1.20 Precedence: list List-Id: "Development of OpenBSC, OsmoBSC, OsmoNITB, OsmoCSCN" List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , Cc: Max Errors-To: openbsc-bounces@lists.osmocom.org Sender: "OpenBSC" From: Max Introduce new configuration option bscs-config-file which includes BSC configuration from the given file. Both absolute and relative (to the main config file) paths are supported. Add 'show bscs-config' command to display current BSC configuration. Note: it is still possible to have BSC configuration in the main file (provided proper index number is used) and in runtime but BSC configuration is no longer saved automatically. The management of included configuration file is left to external tools. Update configuration examples. Fixes: OS#1669 Sponsored-by: On-Waves ehf --- openbsc/doc/examples/osmo-bsc_nat/bscs.config | 13 ++++++ openbsc/doc/examples/osmo-bsc_nat/osmo-bsc_nat.cfg | 8 +--- openbsc/include/openbsc/bsc_nat.h | 5 +++ openbsc/osmoappdesc.py | 1 - openbsc/src/osmo-bsc_nat/bsc_nat.c | 5 ++- openbsc/src/osmo-bsc_nat/bsc_nat_vty.c | 49 ++++++++++++++++++++-- 6 files changed, 69 insertions(+), 12 deletions(-) create mode 100644 openbsc/doc/examples/osmo-bsc_nat/bscs.config diff --git a/openbsc/doc/examples/osmo-bsc_nat/bscs.config b/openbsc/doc/examples/osmo-bsc_nat/bscs.config new file mode 100644 index 0000000..176debe --- /dev/null +++ b/openbsc/doc/examples/osmo-bsc_nat/bscs.config @@ -0,0 +1,13 @@ +nat + bsc 0 + token lol + location_area_code 1234 + description bsc + max-endpoints 32 + paging forbidden 0 + bsc 1 + token wat + location_area_code 5678 + description bsc + max-endpoints 32 + paging forbidden 0 diff --git a/openbsc/doc/examples/osmo-bsc_nat/osmo-bsc_nat.cfg b/openbsc/doc/examples/osmo-bsc_nat/osmo-bsc_nat.cfg index 737d104..2e00bc2 100644 --- a/openbsc/doc/examples/osmo-bsc_nat/osmo-bsc_nat.cfg +++ b/openbsc/doc/examples/osmo-bsc_nat/osmo-bsc_nat.cfg @@ -62,11 +62,5 @@ nat timeout ping 20 timeout pong 5 ip-dscp 0 + bscs-config-file bscs.config access-list bla imsi-allow ^11$ - - bsc 0 - token bla - location_area_code 1234 - description bsc - max-endpoints 32 - paging forbidden 0 diff --git a/openbsc/include/openbsc/bsc_nat.h b/openbsc/include/openbsc/bsc_nat.h index c5fefe1..5ccc02e 100644 --- a/openbsc/include/openbsc/bsc_nat.h +++ b/openbsc/include/openbsc/bsc_nat.h @@ -264,6 +264,11 @@ struct bsc_nat { struct bsc_endpoint *bsc_endpoints; + /* path to file with BSC config */ + char *include_file; + char *include_base; + char *resolved_path; + /* filter */ char *acc_lst_name; diff --git a/openbsc/osmoappdesc.py b/openbsc/osmoappdesc.py index 76f03fc..50d7bf0 100644 --- a/openbsc/osmoappdesc.py +++ b/openbsc/osmoappdesc.py @@ -26,7 +26,6 @@ nitb_e1_configs = [ "doc/examples/osmo-nitb/rbs2308/openbsc.cfg" ] - app_configs = { "osmo-bsc": ["doc/examples/osmo-bsc/osmo-bsc.cfg"], "nat": ["doc/examples/osmo-bsc_nat/osmo-bsc_nat.cfg"], diff --git a/openbsc/src/osmo-bsc_nat/bsc_nat.c b/openbsc/src/osmo-bsc_nat/bsc_nat.c index ab82adf..f433324 100644 --- a/openbsc/src/osmo-bsc_nat/bsc_nat.c +++ b/openbsc/src/osmo-bsc_nat/bsc_nat.c @@ -34,6 +34,7 @@ #include #include #include +#include #define _GNU_SOURCE #include @@ -1626,6 +1627,8 @@ int main(int argc, char **argv) local_addr.s_addr = INADDR_ANY; handle_options(argc, argv); + nat->include_base = dirname(talloc_strdup(tall_bsc_ctx, config_file)); + rate_ctr_init(tall_bsc_ctx); osmo_stats_init(tall_bsc_ctx); @@ -1651,7 +1654,7 @@ int main(int argc, char **argv) /* seed the PRNG */ srand(time(NULL)); - + LOGP(DNAT, LOGL_NOTICE, "BSCs configured from %s\n", nat->resolved_path); /* * Setup the MGCP code.. diff --git a/openbsc/src/osmo-bsc_nat/bsc_nat_vty.c b/openbsc/src/osmo-bsc_nat/bsc_nat_vty.c index 4348d6f..b7b49e6 100644 --- a/openbsc/src/osmo-bsc_nat/bsc_nat_vty.c +++ b/openbsc/src/osmo-bsc_nat/bsc_nat_vty.c @@ -96,6 +96,8 @@ static int config_write_nat(struct vty *vty) vty_out(vty, " timeout auth %d%s", _nat->auth_timeout, VTY_NEWLINE); vty_out(vty, " timeout ping %d%s", _nat->ping_timeout, VTY_NEWLINE); vty_out(vty, " timeout pong %d%s", _nat->pong_timeout, VTY_NEWLINE); + if (_nat->include_file) + vty_out(vty, " bscs-config-file %s%s", _nat->include_file, VTY_NEWLINE); if (_nat->token) vty_out(vty, " token %s%s", _nat->token, VTY_NEWLINE); vty_out(vty, " ip-dscp %d%s", _nat->bsc_ip_dscp, VTY_NEWLINE); @@ -181,6 +183,14 @@ static int config_write_bsc(struct vty *vty) return CMD_SUCCESS; } +DEFUN(show_bscs, show_bscs_cmd, "show bscs-config", + SHOW_STR "Show configured BSCs\n" + "Both from included file and vty\n") +{ + vty_out(vty, "BSCs configuration loaded from %s:%s", _nat->resolved_path, + VTY_NEWLINE); + return config_write_bsc(vty); +} DEFUN(show_sccp, show_sccp_cmd, "show sccp connections", SHOW_STR "Display information about SCCP\n" @@ -495,6 +505,34 @@ DEFUN(cfg_nat_acc_lst_name, return CMD_SUCCESS; } +DEFUN(cfg_nat_include, + cfg_nat_include_cmd, + "bscs-config-file NAME", + "Set the filename of the BSC configuration to include.\n" + "The filename to be included.") +{ + char *path; + int rc; + + if ('/' == argv[0][0]) + bsc_replace_string(_nat, &_nat->resolved_path, argv[0]); + else { + path = talloc_asprintf(_nat, "%s/%s", _nat->include_base, + argv[0]); + bsc_replace_string(_nat, &_nat->resolved_path, path); + talloc_free(path); + } + + rc = vty_read_config_file(_nat->resolved_path, NULL); + if (rc < 0) { + vty_out(vty, "Failed to parse the config file %s: %s%s", + _nat->resolved_path, strerror(-rc), VTY_NEWLINE); + return CMD_WARNING; + } + bsc_replace_string(_nat, &_nat->include_file, argv[0]); + return CMD_SUCCESS; +} + DEFUN(cfg_nat_no_acc_lst_name, cfg_nat_no_acc_lst_name_cmd, "no access-list-name", @@ -865,8 +903,11 @@ DEFUN(cfg_bsc_lac, cfg_bsc_lac_cmd, "location_area_code <0-65535>", /* verify that the LACs are unique */ llist_for_each_entry(tmp, &_nat->bsc_configs, entry) { if (bsc_config_handles_lac(tmp, lac)) { - vty_out(vty, "%% LAC %d is already used.%s", lac, VTY_NEWLINE); - return CMD_ERR_INCOMPLETE; + if (tmp->nr != conf->nr) { + vty_out(vty, "%% LAC %d is already used.%s", lac, + VTY_NEWLINE); + return CMD_ERR_INCOMPLETE; + } } } @@ -1179,6 +1220,7 @@ int bsc_nat_vty_init(struct bsc_nat *nat) install_element_ve(&show_msc_cmd); install_element_ve(&test_regex_cmd); install_element_ve(&show_bsc_mgcp_cmd); + install_element_ve(&show_bscs_cmd); install_element_ve(&show_bar_lst_cmd); install_element_ve(&show_prefix_tree_cmd); install_element_ve(&show_ussd_connection_cmd); @@ -1200,6 +1242,7 @@ int bsc_nat_vty_init(struct bsc_nat *nat) install_element(NAT_NODE, &cfg_nat_bsc_ip_tos_cmd); install_element(NAT_NODE, &cfg_nat_acc_lst_name_cmd); install_element(NAT_NODE, &cfg_nat_no_acc_lst_name_cmd); + install_element(NAT_NODE, &cfg_nat_include_cmd); install_element(NAT_NODE, &cfg_nat_imsi_black_list_fn_cmd); install_element(NAT_NODE, &cfg_nat_no_imsi_black_list_fn_cmd); install_element(NAT_NODE, &cfg_nat_ussd_lst_name_cmd); @@ -1236,7 +1279,7 @@ int bsc_nat_vty_init(struct bsc_nat *nat) /* BSC subgroups */ install_element(NAT_NODE, &cfg_bsc_cmd); - install_node(&bsc_node, config_write_bsc); + install_node(&bsc_node, NULL); vty_install_default(NAT_BSC_NODE); install_element(NAT_BSC_NODE, &cfg_bsc_token_cmd); install_element(NAT_BSC_NODE, &cfg_bsc_auth_key_cmd);