@@ -1452,7 +1452,7 @@ static int do_reset(struct ibmvnic_adapter *adapter,
rc = ibmvnic_init(adapter);
if (rc)
- return 0;
+ return IBMVNIC_INIT_FAILED;
/* If the adapter was in PROBE state prior to the reset,
* exit here.
@@ -1555,7 +1555,7 @@ static void __ibmvnic_reset(struct work_struct *work)
while (rwi) {
rc = do_reset(adapter, rwi, reset_state);
kfree(rwi);
- if (rc)
+ if (rc && rc != IBMVNIC_INIT_FAILED)
break;
rwi = get_next_rwi(adapter);
@@ -30,6 +30,8 @@
#define IBMVNIC_DRIVER_VERSION "1.0.1"
#define IBMVNIC_INVALID_MAP -1
#define IBMVNIC_STATS_TIMEOUT 1
+#define IBMVNIC_INIT_FAILED 2
+
/* basic structures plus 100 2k buffers */
#define IBMVNIC_IO_ENTITLEMENT_DEFAULT 610305
For all non-fatal reset conditions, the hypervisor will send a failover when we attempt to initialize the crq and the vnic client is expected to handle that failover instead of the existing non-fatal reset. To handle this, we need to return from init with a return code that indicates that we have hit this case. Signed-off-by: John Allen <jallen@linux.vnet.ibm.com> ---