diff mbox series

[v9,07/11] pwm: sifive: Use 64-bit division macro

Message ID c6a4191f4e0d75f086100f9f667e8894f6f7bef6.1584473399.git.gurus@codeaurora.org
State Changes Requested
Headers show
Series [v9,01/11] drm/i915: Use 64-bit division macro | expand

Commit Message

Guru Das Srinagesh March 17, 2020, 8:05 p.m. UTC
Since the PWM framework is switching struct pwm_args.period's datatype
to u64, prepare for this transition by using DIV64_U64_ROUND_CLOSEST to
handle a 64-bit divisor.

Cc: Palmer Dabbelt <palmer@dabbelt.com>
Cc: Paul Walmsley <paul.walmsley@sifive.com>
Cc: linux-riscv@lists.infradead.org
Cc: Yash Shah <yash.shah@sifive.com>
Cc: Atish Patra <atish.patra@wdc.com>
Cc: Ding Xiang <dingxiang@cmss.chinamobile.com>
Cc: Wesley W. Terpstra <wesley@sifive.com>

Signed-off-by: Guru Das Srinagesh <gurus@codeaurora.org>
---
 drivers/pwm/pwm-sifive.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
diff mbox series

Patch

diff --git a/drivers/pwm/pwm-sifive.c b/drivers/pwm/pwm-sifive.c
index cc63f9b..62de0bb 100644
--- a/drivers/pwm/pwm-sifive.c
+++ b/drivers/pwm/pwm-sifive.c
@@ -181,7 +181,7 @@  static int pwm_sifive_apply(struct pwm_chip *chip, struct pwm_device *pwm,
 	 * consecutively
 	 */
 	num = (u64)duty_cycle * (1U << PWM_SIFIVE_CMPWIDTH);
-	frac = DIV_ROUND_CLOSEST_ULL(num, state->period);
+	frac = DIV64_U64_ROUND_CLOSEST(num, state->period);
 	/* The hardware cannot generate a 100% duty cycle */
 	frac = min(frac, (1U << PWM_SIFIVE_CMPWIDTH) - 1);