diff mbox

[v6,1/2] libata-scsi: reject WRITE SAME (16) with n_block that exceeds limit

Message ID 844c07e66ad6d410029d80e6b32e8f1480fa9f47.1468354842.git.tom.ty89@gmail.com
State Not Applicable
Delegated to: David Miller
Headers show

Commit Message

Tom Yan July 12, 2016, 8:31 p.m. UTC
From: Tom Yan <tom.ty89@gmail.com>

Currently if a WRITE SAME (16) command is issued to the SATL with
"number of blocks" that is larger than the "Maximum write same length"
(which is the maximum number of blocks per TRIM command allowed in
libata, currently 65535 * 512 / 8 blocks), the SATL will accept the
command and translate it to a TRIM command with the upper limit.

However, according to SBC (as of sbc4r11.pdf), the "device server"
should terminate the command with "Invalid field in CDB" in that case.

Signed-off-by: Tom Yan <tom.ty89@gmail.com>
diff mbox

Patch

diff --git a/drivers/ata/libata-scsi.c b/drivers/ata/libata-scsi.c
index bfec66f..392aebb 100644
--- a/drivers/ata/libata-scsi.c
+++ b/drivers/ata/libata-scsi.c
@@ -3305,7 +3305,13 @@  static unsigned int ata_scsi_write_same_xlat(struct ata_queued_cmd *qc)
 		goto invalid_param_len;
 
 	buf = page_address(sg_page(scsi_sglist(scmd)));
-	size = ata_set_lba_range_entries(buf, 512, block, n_block);
+
+	if (n_block <= 65535 * 512 / 8) {
+		size = ata_set_lba_range_entries(buf, 512, block, n_block);
+	} else {
+		fp = 2;
+		goto invalid_fld;
+	}
 
 	if (ata_ncq_enabled(dev) && ata_fpdma_dsm_supported(dev)) {
 		/* Newer devices support queued TRIM commands */