From patchwork Fri Jun 9 18:33:18 2017 Content-Type: text/plain; charset="utf-8" MIME-Version: 1.0 Content-Transfer-Encoding: 7bit X-Patchwork-Submitter: Jan Kiszka X-Patchwork-Id: 774115 Return-Path: X-Original-To: incoming@patchwork.ozlabs.org Delivered-To: patchwork-incoming@bilbo.ozlabs.org Received: from vger.kernel.org (vger.kernel.org [209.132.180.67]) by ozlabs.org (Postfix) with ESMTP id 3wkrYz07D1z9s81 for ; Sat, 10 Jun 2017 04:35:03 +1000 (AEST) Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S1751835AbdFISdf (ORCPT ); Fri, 9 Jun 2017 14:33:35 -0400 Received: from david.siemens.de ([192.35.17.14]:54950 "EHLO david.siemens.de" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1751809AbdFISdc (ORCPT ); Fri, 9 Jun 2017 14:33:32 -0400 Received: from mail2.siemens.de (mail2.siemens.de [139.25.208.11]) by david.siemens.de (8.15.2/8.15.2) with ESMTPS id v59IXJmk010156 (version=TLSv1.2 cipher=DHE-RSA-AES256-GCM-SHA384 bits=256 verify=OK); Fri, 9 Jun 2017 20:33:19 +0200 Received: from md1f2u6c.ww002.siemens.net.net ([139.25.68.37]) by mail2.siemens.de (8.15.2/8.15.2) with ESMTP id v59IXJUx007870; Fri, 9 Jun 2017 20:33:19 +0200 From: Jan Kiszka To: Linus Walleij , Alexandre Courbot Cc: Greg Kroah-Hartman , Linux Kernel Mailing List , linux-serial@vger.kernel.org, linux-gpio@vger.kernel.org, Sudip Mukherjee , Andy Shevchenko , Sascha Weisenberger Subject: [PATCH v6 10/10] serial: exar: Add support for IOT2040 device Date: Fri, 9 Jun 2017 20:33:18 +0200 Message-Id: <47c8206a1f97b6c987dfb8761805317406ab1a34.1497033197.git.jan.kiszka@siemens.com> X-Mailer: git-send-email 2.12.3 In-Reply-To: References: In-Reply-To: References: Sender: linux-gpio-owner@vger.kernel.org Precedence: bulk List-ID: X-Mailing-List: linux-gpio@vger.kernel.org This implements the setup of RS232 and the switch-over to RS485 or RS422 for the Siemens IOT2040. That uses an EXAR XR17V352 with external logic to switch between the different modes. The external logic is controlled via MPIO pins of the EXAR controller. Only pin 10 can be exported as GPIO on the IOT2040. It is connected to an LED. As the XR17V352 used on the IOT2040 is not equipped with an external EEPROM, it cannot present itself as IOT2040-variant via subvendor/ subdevice IDs. Thus, we have to check via DMI for the target platform. Co-developed with Sascha Weisenberger. Signed-off-by: Sascha Weisenberger Signed-off-by: Jan Kiszka Reviewed-by: Andy Shevchenko Acked-by: Greg Kroah-Hartman --- drivers/tty/serial/8250/8250_exar.c | 129 +++++++++++++++++++++++++++++++++++- 1 file changed, 128 insertions(+), 1 deletion(-) diff --git a/drivers/tty/serial/8250/8250_exar.c b/drivers/tty/serial/8250/8250_exar.c index 95c6e24ebff1..6dfa7b86501f 100644 --- a/drivers/tty/serial/8250/8250_exar.c +++ b/drivers/tty/serial/8250/8250_exar.c @@ -10,6 +10,7 @@ * the Free Software Foundation; either version 2 of the License. */ #include +#include #include #include #include @@ -62,6 +63,43 @@ #define UART_EXAR_MPIOSEL_15_8 0x99 /* MPIOSEL[15:8] */ #define UART_EXAR_MPIOOD_15_8 0x9a /* MPIOOD[15:8] */ +#define UART_EXAR_RS485_DLY(x) ((x) << 4) + +/* + * IOT2040 MPIO wiring semantics: + * + * MPIO Port Function + * ---- ---- -------- + * 0 2 Mode bit 0 + * 1 2 Mode bit 1 + * 2 2 Terminate bus + * 3 - + * 4 3 Mode bit 0 + * 5 3 Mode bit 1 + * 6 3 Terminate bus + * 7 - + * 8 2 Enable + * 9 3 Enable + * 10 - Red LED + * 11..15 - + */ + +/* IOT2040 MPIOs 0..7 */ +#define IOT2040_UART_MODE_RS232 0x01 +#define IOT2040_UART_MODE_RS485 0x02 +#define IOT2040_UART_MODE_RS422 0x03 +#define IOT2040_UART_TERMINATE_BUS 0x04 + +#define IOT2040_UART1_MASK 0x0f +#define IOT2040_UART2_SHIFT 4 + +#define IOT2040_UARTS_DEFAULT_MODE 0x11 /* both RS232 */ +#define IOT2040_UARTS_GPIO_LO_MODE 0x88 /* reserved pins as input */ + +/* IOT2040 MPIOs 8..15 */ +#define IOT2040_UARTS_ENABLE 0x03 +#define IOT2040_UARTS_GPIO_HI_MODE 0xF8 /* enable & LED as outputs */ + struct exar8250; struct exar8250_platform { @@ -243,18 +281,107 @@ static const struct exar8250_platform exar8250_default_platform = { .register_gpio = xr17v35x_register_gpio, }; +static int iot2040_rs485_config(struct uart_port *port, + struct serial_rs485 *rs485) +{ + bool is_rs485 = !!(rs485->flags & SER_RS485_ENABLED); + u8 __iomem *p = port->membase; + u8 mask = IOT2040_UART1_MASK; + u8 mode, value; + + if (is_rs485) { + if (rs485->flags & SER_RS485_RX_DURING_TX) + mode = IOT2040_UART_MODE_RS422; + else + mode = IOT2040_UART_MODE_RS485; + + if (rs485->flags & SER_RS485_TERMINATE_BUS) + mode |= IOT2040_UART_TERMINATE_BUS; + } else { + mode = IOT2040_UART_MODE_RS232; + } + + if (port->line == 3) { + mask <<= IOT2040_UART2_SHIFT; + mode <<= IOT2040_UART2_SHIFT; + } + + value = readb(p + UART_EXAR_MPIOLVL_7_0); + value &= ~mask; + value |= mode; + writeb(value, p + UART_EXAR_MPIOLVL_7_0); + + value = readb(p + UART_EXAR_FCTR); + if (is_rs485) + value |= UART_FCTR_EXAR_485; + else + value &= ~UART_FCTR_EXAR_485; + writeb(value, p + UART_EXAR_FCTR); + + if (is_rs485) + writeb(UART_EXAR_RS485_DLY(4), p + UART_MSR); + + port->rs485 = *rs485; + + return 0; +} + +static const struct property_entry iot2040_gpio_properties[] = { + PROPERTY_ENTRY_U32("linux,first-pin", 10), + PROPERTY_ENTRY_U32("ngpios", 1), + { } +}; + +static int iot2040_register_gpio(struct pci_dev *pcidev, + struct uart_8250_port *port) +{ + u8 __iomem *p = port->port.membase; + + writeb(IOT2040_UARTS_DEFAULT_MODE, p + UART_EXAR_MPIOLVL_7_0); + writeb(IOT2040_UARTS_GPIO_LO_MODE, p + UART_EXAR_MPIOSEL_7_0); + writeb(IOT2040_UARTS_ENABLE, p + UART_EXAR_MPIOLVL_15_8); + writeb(IOT2040_UARTS_GPIO_HI_MODE, p + UART_EXAR_MPIOSEL_15_8); + + port->port.private_data = + __xr17v35x_register_gpio(pcidev, iot2040_gpio_properties); + + return 0; +} + +static const struct exar8250_platform iot2040_platform = { + .rs485_config = iot2040_rs485_config, + .register_gpio = iot2040_register_gpio, +}; + +static const struct dmi_system_id exar_platforms[] = { + { + .matches = { + DMI_EXACT_MATCH(DMI_BOARD_NAME, "SIMATIC IOT2000"), + DMI_EXACT_MATCH(DMI_BOARD_ASSET_TAG, + "6ES7647-0AA00-1YA2"), + }, + .driver_data = (void *)&iot2040_platform, + }, + {} +}; + static int pci_xr17v35x_setup(struct exar8250 *priv, struct pci_dev *pcidev, struct uart_8250_port *port, int idx) { const struct exar8250_board *board = priv->board; const struct exar8250_platform *platform; + const struct dmi_system_id *dmi_match; unsigned int offset = idx * 0x400; unsigned int baud = 7812500; u8 __iomem *p; int ret; - platform = &exar8250_default_platform; + dmi_match = dmi_first_match(exar_platforms); + if (dmi_match) + platform = dmi_match->driver_data; + else + platform = &exar8250_default_platform; port->port.uartclk = baud * 16; port->port.rs485_config = platform->rs485_config;