new file mode 100644
@@ -0,0 +1,84 @@
+NXP LPC1850 Reset Generation Unit (RGU)
+========================================
+
+Please also refer to reset.txt in this directory for common reset
+controller binding usage.
+
+Required properties:
+- compatible: Should be "nxp,lpc1850-rgu"
+- reg: register base and length
+- clocks: phandle and clock specifier to RGU clocks
+- clock-names: should contain "delay" and "reg"
+- #reset-cells: should be 1
+
+See table below for valid peripheral reset numbers. Numbers not
+in the table below are either reserved or not applicable for
+normal operation.
+
+Reset Peripheral
+ 9 System control unit (SCU)
+ 12 ARM Cortex-M0 subsystem core (LPC43xx only)
+ 13 CPU core
+ 16 LCD controller
+ 17 USB0
+ 18 USB1
+ 19 DMA
+ 20 SDIO
+ 21 External memory controller (EMC)
+ 22 Ethernet
+ 25 Flash bank A
+ 27 EEPROM
+ 28 GPIO
+ 29 Flash bank B
+ 32 Timer0
+ 33 Timer1
+ 34 Timer2
+ 35 Timer3
+ 36 Repetitive Interrupt timer (RIT)
+ 37 State Configurable Timer (SCT)
+ 38 Motor control PWM (MCPWM)
+ 39 QEI
+ 40 ADC0
+ 41 ADC1
+ 42 DAC
+ 44 USART0
+ 45 UART1
+ 46 USART2
+ 47 USART3
+ 48 I2C0
+ 49 I2C1
+ 50 SSP0
+ 51 SSP1
+ 52 I2S0 and I2S1
+ 53 Serial Flash Interface (SPIFI)
+ 54 C_CAN1
+ 55 C_CAN0
+ 56 ARM Cortex-M0 application core (LPC4370 only)
+ 57 SGPIO (LPC43xx only)
+ 58 SPI (LPC43xx only)
+ 60 ADCHS (12-bit ADC) (LPC4370 only)
+
+Refer to NXP LPC18xx or LPC43xx user manual for more details about
+the reset signals and the connected block/peripheral.
+
+Reset provider example:
+rgu: reset-controller@40053000 {
+ compatible = "nxp,lpc1850-rgu";
+ reg = <0x40053000 0x1000>;
+ clocks = <&cgu BASE_SAFE_CLK>, <&ccu1 CLK_CPU_BUS>;
+ clock-names = "delay", "reg";
+ #reset-cells = <1>;
+};
+
+Reset consumer example:
+mac: ethernet@40010000 {
+ compatible = "nxp,lpc1850-dwmac", "snps,dwmac-3.611", "snps,dwmac";
+ reg = <0x40010000 0x2000>;
+ interrupts = <5>;
+ interrupt-names = "macirq";
+ clocks = <&ccu1 CLK_CPU_ETHERNET>;
+ clock-names = "stmmaceth";
+ resets = <&rgu 22>;
+ reset-names = "stmmaceth";
+ status = "disabled";
+};
Add device tree binding documentation for the Reset Generation Unit (RGU) found on NXP LPC18xx and LPC43xx devies. This documentation also includes a table which shows the RGU reset number and the connected peripheral. Signed-off-by: Joachim Eastwood <manabian@gmail.com> --- .../devicetree/bindings/reset/nxp,lpc1850-rgu.txt | 84 ++++++++++++++++++++++ 1 file changed, 84 insertions(+) create mode 100644 Documentation/devicetree/bindings/reset/nxp,lpc1850-rgu.txt