Hi Stefano, On Fri, Sep 21, 2018 at 9:05 PM, Stefano Babic <sbabic@denx.de> wrote: > It can be useful to run SWUpdate with -c option on the > target while the daemon was already startd. This is currently > forbidden because the notifier tries to bind to the same > abstract socket. Add an enumeration to the socket to > let a second instance to start successfully. > > Signed-off-by: Stefano Babic <sbabic@denx.de> I like the idea. Works as expected for me, so: Tested-by: Diego Rondini <diego.rondini@kynetics.com> > --- > core/notifier.c | 33 +++++++++++++++++++++++++++------ > 1 file changed, 27 insertions(+), 6 deletions(-) > > diff --git a/core/notifier.c b/core/notifier.c > index e2a37df..8643c6f 100644 > --- a/core/notifier.c > +++ b/core/notifier.c > @@ -259,6 +259,7 @@ static void *notifier_thread (void __attribute__ ((__unused__)) *data) > { > int serverfd; > int len; > + int attempt = 0; > struct notify_ipc_msg msg; > > /* Initialize and bind to UDS */ > @@ -272,12 +273,27 @@ static void *notifier_thread (void __attribute__ ((__unused__)) *data) > setup_socket_cleanup(¬ify_server); > #endif > > - if (bind(serverfd, (const struct sockaddr *) ¬ify_server, > + int len_socket_name = strlen(¬ify_server.sun_path[1]); > + > + do { > + errno = 0; > + if (bind(serverfd, (const struct sockaddr *) ¬ify_server, > sizeof(struct sockaddr_un)) < 0) { > - fprintf(stderr, "Error binding notifier socket: %s, exiting.\n", strerror(errno)); > - close(serverfd); > - exit(2); > - } > + if (errno == EADDRINUSE && attempt < 10) { > + attempt++; > + /* > + * Start increasing the socket as > + * NotifyServer1, NotifyServer2... > + */ > + notify_server.sun_path[len_socket_name + 1] = '0' + attempt; > + } else { > + fprintf(stderr, "Error binding notifier socket: %s, exiting.\n", strerror(errno)); > + close(serverfd); > + exit(2); > + } > + } else > + break; > + } while (1); > > do { > len = recvfrom(serverfd, &msg, sizeof(msg), 0, NULL, NULL); > @@ -291,7 +307,6 @@ static void *notifier_thread (void __attribute__ ((__unused__)) *data) > > void notify_init(void) > { > - addr_init(¬ify_server, "NotifyServer"); > > #ifdef CONFIG_SYSTEMD > /* > @@ -341,6 +356,12 @@ void notify_init(void) > return; > } > } else { > + /* > + * If this is the main process, start setting the name of the > + * socket. This can changed if more as one instance of swupdate > + * is started (name adjusted to avoid adrress is in use) > + */ > + addr_init(¬ify_server, "NotifyServer"); > STAILQ_INIT(&clients); > register_notifier(console_notifier); > register_notifier(process_notifier); > -- > 2.17.1 Best regards, Diego Rondini Sr. Embedded Engineer Kynetics www.kynetics.com
diff --git a/core/notifier.c b/core/notifier.c index e2a37df..8643c6f 100644 --- a/core/notifier.c +++ b/core/notifier.c @@ -259,6 +259,7 @@ static void *notifier_thread (void __attribute__ ((__unused__)) *data) { int serverfd; int len; + int attempt = 0; struct notify_ipc_msg msg; /* Initialize and bind to UDS */ @@ -272,12 +273,27 @@ static void *notifier_thread (void __attribute__ ((__unused__)) *data) setup_socket_cleanup(¬ify_server); #endif - if (bind(serverfd, (const struct sockaddr *) ¬ify_server, + int len_socket_name = strlen(¬ify_server.sun_path[1]); + + do { + errno = 0; + if (bind(serverfd, (const struct sockaddr *) ¬ify_server, sizeof(struct sockaddr_un)) < 0) { - fprintf(stderr, "Error binding notifier socket: %s, exiting.\n", strerror(errno)); - close(serverfd); - exit(2); - } + if (errno == EADDRINUSE && attempt < 10) { + attempt++; + /* + * Start increasing the socket as + * NotifyServer1, NotifyServer2... + */ + notify_server.sun_path[len_socket_name + 1] = '0' + attempt; + } else { + fprintf(stderr, "Error binding notifier socket: %s, exiting.\n", strerror(errno)); + close(serverfd); + exit(2); + } + } else + break; + } while (1); do { len = recvfrom(serverfd, &msg, sizeof(msg), 0, NULL, NULL); @@ -291,7 +307,6 @@ static void *notifier_thread (void __attribute__ ((__unused__)) *data) void notify_init(void) { - addr_init(¬ify_server, "NotifyServer"); #ifdef CONFIG_SYSTEMD /* @@ -341,6 +356,12 @@ void notify_init(void) return; } } else { + /* + * If this is the main process, start setting the name of the + * socket. This can changed if more as one instance of swupdate + * is started (name adjusted to avoid adrress is in use) + */ + addr_init(¬ify_server, "NotifyServer"); STAILQ_INIT(&clients); register_notifier(console_notifier); register_notifier(process_notifier);
It can be useful to run SWUpdate with -c option on the target while the daemon was already startd. This is currently forbidden because the notifier tries to bind to the same abstract socket. Add an enumeration to the socket to let a second instance to start successfully. Signed-off-by: Stefano Babic <sbabic@denx.de> --- core/notifier.c | 33 +++++++++++++++++++++++++++------ 1 file changed, 27 insertions(+), 6 deletions(-)