Chris Packham Jan. 22, 2018, 9:44 a.m. UTC
Erratum NO. FE-9144572: The device SPI interface supports frequencies of
up to 50 MHz.  However, due to this erratum, when the device core clock
is 250 MHz and the SPI interfaces is configured for 50MHz SPI clock and
CPOL=CPHA=1 there might occur data corruption on reads from the SPI
device.

Implement the workaround by setting the TMISO_SAMPLE value to 0x2
in the timing1 register.

Signed-off-by: Chris Packham <judge.packham@gmail.com>
Reviewed-by: Stefan Roese <sr@denx.de>
Reviewed-by: Jagan Teki <jagan@openedev.com>
---
I've based this as much as I can on the equivalent implementation in the
Linux kernel[1], but there are differences in the u-boot spi
infrastructure that means I can't be as specific when qualifying whether
the workaround is needed.

[1] - https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/tree/drivers/spi/spi-orion.c#n248

Changes in v4:
- move comment to function to match equivalent linux code
- collect review from Jagan

Changes in v3:
- initialise drv_data for Armada XP and 375

Changes in v2:
- collect reviewed-by from Stefan
- remove mvebu_spi_type
- describe errata above mvebu_spi_50mhz_ac_timing_erratum

 arch/arm/include/asm/arch-mvebu/spi.h |  6 +++
 drivers/spi/kirkwood_spi.c            | 69 +++++++++++++++++++++++++++++++++--
 2 files changed, 72 insertions(+), 3 deletions(-)

Comments

Jagan Teki Jan. 22, 2018, 9:53 a.m. UTC | #1
On Mon, Jan 22, 2018 at 3:14 PM, Chris Packham <judge.packham@gmail.com> wrote:
> Erratum NO. FE-9144572: The device SPI interface supports frequencies of
> up to 50 MHz.  However, due to this erratum, when the device core clock
> is 250 MHz and the SPI interfaces is configured for 50MHz SPI clock and
> CPOL=CPHA=1 there might occur data corruption on reads from the SPI
> device.
>
> Implement the workaround by setting the TMISO_SAMPLE value to 0x2
> in the timing1 register.
>
> Signed-off-by: Chris Packham <judge.packham@gmail.com>
> Reviewed-by: Stefan Roese <sr@denx.de>
> Reviewed-by: Jagan Teki <jagan@openedev.com>
> ---

Applied to u-boot-spi/master
diff mbox series

Patch

diff --git a/arch/arm/include/asm/arch-mvebu/spi.h b/arch/arm/include/asm/arch-mvebu/spi.h
index 3545aed17347..1de510ea6da9 100644
--- a/arch/arm/include/asm/arch-mvebu/spi.h
+++ b/arch/arm/include/asm/arch-mvebu/spi.h
@@ -57,6 +57,12 @@  struct kwspi_registers {
 #define KWSPI_TXLSBF		(1 << 13)
 #define KWSPI_RXLSBF		(1 << 14)
 
+/* Timing Parameters 1 Register */
+#define KW_SPI_TMISO_SAMPLE_OFFSET	6
+#define KW_SPI_TMISO_SAMPLE_MASK	(0x3 << KW_SPI_TMISO_SAMPLE_OFFSET)
+#define KW_SPI_TMISO_SAMPLE_1		(1 << KW_SPI_TMISO_SAMPLE_OFFSET)
+#define KW_SPI_TMISO_SAMPLE_2		(2 << KW_SPI_TMISO_SAMPLE_OFFSET)
+
 #define KWSPI_IRQUNMASK		1 /* unmask SPI interrupt */
 #define KWSPI_IRQMASK		0 /* mask SPI interrupt */
 #define KWSPI_SMEMRDIRQ		1 /* SerMem data xfer ready irq */
diff --git a/drivers/spi/kirkwood_spi.c b/drivers/spi/kirkwood_spi.c
index 0c6bd295cde9..1ad8cdee6491 100644
--- a/drivers/spi/kirkwood_spi.c
+++ b/drivers/spi/kirkwood_spi.c
@@ -243,6 +243,10 @@  int spi_xfer(struct spi_slave *slave, unsigned int bitlen,
 
 /* Here now the DM part */
 
+struct mvebu_spi_dev {
+	bool			is_errata_50mhz_ac;
+};
+
 struct mvebu_spi_platdata {
 	struct kwspi_registers *spireg;
 };
@@ -269,10 +273,44 @@  static int mvebu_spi_set_speed(struct udevice *bus, uint hz)
 	return 0;
 }
 
+static void mvebu_spi_50mhz_ac_timing_erratum(struct udevice *bus, uint mode)
+{
+	struct mvebu_spi_platdata *plat = dev_get_platdata(bus);
+	struct kwspi_registers *reg = plat->spireg;
+	u32 data;
+
+	/*
+	 * Erratum description: (Erratum NO. FE-9144572) The device
+	 * SPI interface supports frequencies of up to 50 MHz.
+	 * However, due to this erratum, when the device core clock is
+	 * 250 MHz and the SPI interfaces is configured for 50MHz SPI
+	 * clock and CPOL=CPHA=1 there might occur data corruption on
+	 * reads from the SPI device.
+	 * Erratum Workaround:
+	 * Work in one of the following configurations:
+	 * 1. Set CPOL=CPHA=0 in "SPI Interface Configuration
+	 * Register".
+	 * 2. Set TMISO_SAMPLE value to 0x2 in "SPI Timing Parameters 1
+	 * Register" before setting the interface.
+	 */
+	data = readl(&reg->timing1);
+	data &= ~KW_SPI_TMISO_SAMPLE_MASK;
+
+	if (CONFIG_SYS_TCLK == 250000000 &&
+	    mode & SPI_CPOL &&
+	    mode & SPI_CPHA)
+		data |= KW_SPI_TMISO_SAMPLE_2;
+	else
+		data |= KW_SPI_TMISO_SAMPLE_1;
+
+	writel(data, &reg->timing1);
+}
+
 static int mvebu_spi_set_mode(struct udevice *bus, uint mode)
 {
 	struct mvebu_spi_platdata *plat = dev_get_platdata(bus);
 	struct kwspi_registers *reg = plat->spireg;
+	const struct mvebu_spi_dev *drvdata;
 	u32 data = readl(&reg->cfg);
 
 	data &= ~(KWSPI_CPHA | KWSPI_CPOL | KWSPI_RXLSBF | KWSPI_TXLSBF);
@@ -286,6 +324,10 @@  static int mvebu_spi_set_mode(struct udevice *bus, uint mode)
 
 	writel(data, &reg->cfg);
 
+	drvdata = (struct mvebu_spi_dev *)dev_get_driver_data(bus);
+	if (drvdata->is_errata_50mhz_ac)
+		mvebu_spi_50mhz_ac_timing_erratum(bus, mode);
+
 	return 0;
 }
 
@@ -343,10 +385,31 @@  static const struct dm_spi_ops mvebu_spi_ops = {
 	 */
 };
 
+static const struct mvebu_spi_dev armada_xp_spi_dev_data = {
+	.is_errata_50mhz_ac = false,
+};
+
+static const struct mvebu_spi_dev armada_375_spi_dev_data = {
+	.is_errata_50mhz_ac = false,
+};
+
+static const struct mvebu_spi_dev armada_380_spi_dev_data = {
+	.is_errata_50mhz_ac = true,
+};
+
 static const struct udevice_id mvebu_spi_ids[] = {
-	{ .compatible = "marvell,armada-375-spi" },
-	{ .compatible = "marvell,armada-380-spi" },
-	{ .compatible = "marvell,armada-xp-spi" },
+	{
+		.compatible = "marvell,armada-375-spi",
+		.data = (ulong)&armada_375_spi_dev_data
+	},
+	{
+		.compatible = "marvell,armada-380-spi",
+		.data = (ulong)&armada_380_spi_dev_data
+	},
+	{
+		.compatible = "marvell,armada-xp-spi",
+		.data = (ulong)&armada_xp_spi_dev_data
+	},
 	{ }
 };