Message ID | 20170714125537.14895-28-mario.six@gdsys.cc |
---|---|
State | Rejected, archived |
Delegated to: | Mario Six |
Headers | show |
On 14 July 2017 at 05:55, Mario Six <mario.six@gdsys.cc> wrote: > From: Dirk Eibach <dirk.eibach@gdsys.cc> > > The initialization sequence described in the latest Release Notes > MV-S302033-00 for the Marvell 88E1518 phy omits two register writes. > > Use this new sequence for the setup of this phy. > > Signed-off-by: Dirk Eibach <dirk.eibach@gdsys.cc> > Signed-off-by: Mario Six <mario.six@gdsys.cc> > --- > > board/gdsys/common/phy.c | 2 -- > 1 file changed, 2 deletions(-) Reviewed-by: Simon Glass <sjg@chromium.org>
diff --git a/board/gdsys/common/phy.c b/board/gdsys/common/phy.c index fb92658178..e45f923fed 100644 --- a/board/gdsys/common/phy.c +++ b/board/gdsys/common/phy.c @@ -46,8 +46,6 @@ struct mii_setupcmd fixup_88e1518[] = { { MIICMD_SET, 16, 0x214d }, { MIICMD_SET, 17, 0xcc0c }, { MIICMD_SET, 16, 0x2159 }, - { MIICMD_SET, 22, 0x00fb }, - { MIICMD_SET, 7, 0xc00d }, { MIICMD_SET, 22, 0x0000 }, };