diff mbox

mtd: nand: omap2: Cleanup a curly brace issue

Message ID 20160714212608.GA10856@mwanda
State Superseded
Headers show

Commit Message

Dan Carpenter July 14, 2016, 9:26 p.m. UTC
It doesn't affect runtime, but curly braces were obviously intended.

Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>

Comments

Brian Norris July 14, 2016, 9:31 p.m. UTC | #1
On Fri, Jul 15, 2016 at 12:26:08AM +0300, Dan Carpenter wrote:
> It doesn't affect runtime, but curly braces were obviously intended.
> 
> Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>

Thanks, but you're just a tad late ;)

http://patchwork.ozlabs.org/patch/648283/

Nice to point out that technically, the behavior doesn't really change
though.

Brian

> diff --git a/drivers/mtd/nand/omap2.c b/drivers/mtd/nand/omap2.c
> index a36ad3d..ab7c340 100644
> --- a/drivers/mtd/nand/omap2.c
> +++ b/drivers/mtd/nand/omap2.c
> @@ -1655,10 +1655,11 @@ static int omap_get_dt_info(struct device *dev, struct omap_nand_info *info)
>  
>  	/* detect availability of ELM module. Won't be present pre-OMAP4 */
>  	info->elm_of_node = of_parse_phandle(child, "ti,elm-id", 0);
> -	if (!info->elm_of_node)
> +	if (!info->elm_of_node) {
>  		info->elm_of_node = of_parse_phandle(child, "elm_id", 0);
>  		if (!info->elm_of_node)
>  			dev_dbg(dev, "ti,elm-id not in DT\n");
> +	}
>  
>  	/* select ecc-scheme for NAND */
>  	if (of_property_read_string(child, "ti,nand-ecc-opt", &s)) {
diff mbox

Patch

diff --git a/drivers/mtd/nand/omap2.c b/drivers/mtd/nand/omap2.c
index a36ad3d..ab7c340 100644
--- a/drivers/mtd/nand/omap2.c
+++ b/drivers/mtd/nand/omap2.c
@@ -1655,10 +1655,11 @@  static int omap_get_dt_info(struct device *dev, struct omap_nand_info *info)
 
 	/* detect availability of ELM module. Won't be present pre-OMAP4 */
 	info->elm_of_node = of_parse_phandle(child, "ti,elm-id", 0);
-	if (!info->elm_of_node)
+	if (!info->elm_of_node) {
 		info->elm_of_node = of_parse_phandle(child, "elm_id", 0);
 		if (!info->elm_of_node)
 			dev_dbg(dev, "ti,elm-id not in DT\n");
+	}
 
 	/* select ecc-scheme for NAND */
 	if (of_property_read_string(child, "ti,nand-ecc-opt", &s)) {