diff mbox

[v2,1/2] libata-scsi: fix D_SENSE bit relection in control mode page

Message ID 57853cf5.c193420a.83221.11da@mx.google.com
State Not Applicable
Delegated to: David Miller
Headers show

Commit Message

Tom Yan July 12, 2016, 6:54 p.m. UTC
From: Tom Yan <tom.ty89@gmail.com>

The bit should always be set to 1 when the requested version of
page is "changeable" because we've made it so in ata_mselect_control().
Also, it should always be set to 1 if ATA_DFLAG_D_SENSE is set (when
the requested version of page is "current" or "default").

Signed-off-by: Tom Yan <tom.ty89@gmail.com>
diff mbox

Patch

diff --git a/drivers/ata/libata-scsi.c b/drivers/ata/libata-scsi.c
index bfec66f..7e24f0a 100644
--- a/drivers/ata/libata-scsi.c
+++ b/drivers/ata/libata-scsi.c
@@ -2446,7 +2446,7 @@  static unsigned int ata_msense_ctl_mode(struct ata_device *dev, u8 *buf,
 					bool changeable)
 {
 	modecpy(buf, def_control_mpage, sizeof(def_control_mpage), changeable);
-	if (changeable && (dev->flags & ATA_DFLAG_D_SENSE))
+	if (changeable || (dev->flags & ATA_DFLAG_D_SENSE))
 		buf[2] |= (1 << 2);	/* Descriptor sense requested */
 	return sizeof(def_control_mpage);
 }