[RFC,12/13] arm64: tegra: Add sor-safe clock to DPAUX binding

Message ID 1466165027-17917-13-git-send-email-jonathanh@nvidia.com
State New
Headers show

Commit Message

Jon Hunter June 17, 2016, 12:03 p.m. UTC
Populate the 'sor-safe' clock for DPAUX devices on Tegra210 that require
this clock for operation. Update the compatability string for the DPAUX
instance at address 0x545c0000 to be "nvidia,tegra210-dpaux" to ensure
that the 'sor-safe' clock is enabled for this device.

Signed-off-by: Jon Hunter <jonathanh@nvidia.com>
---
 arch/arm64/boot/dts/nvidia/tegra210.dtsi | 12 +++++++-----
 1 file changed, 7 insertions(+), 5 deletions(-)

Comments

Thierry Reding June 17, 2016, 4:47 p.m. UTC | #1
On Fri, Jun 17, 2016 at 01:03:46PM +0100, Jon Hunter wrote:
> Populate the 'sor-safe' clock for DPAUX devices on Tegra210 that require
> this clock for operation. Update the compatability string for the DPAUX
> instance at address 0x545c0000 to be "nvidia,tegra210-dpaux" to ensure
> that the 'sor-safe' clock is enabled for this device.

Does the second DPAUX need this, too? I have a vague recollection that
they were both slightly different.

Thierry
Jon Hunter June 20, 2016, 9:23 a.m. UTC | #2
On 17/06/16 17:47, Thierry Reding wrote:
> * PGP Signed by an unknown key
> 
> On Fri, Jun 17, 2016 at 01:03:46PM +0100, Jon Hunter wrote:
>> Populate the 'sor-safe' clock for DPAUX devices on Tegra210 that require
>> this clock for operation. Update the compatability string for the DPAUX
>> instance at address 0x545c0000 to be "nvidia,tegra210-dpaux" to ensure
>> that the 'sor-safe' clock is enabled for this device.
> 
> Does the second DPAUX need this, too? I have a vague recollection that
> they were both slightly different.

I have assumed so, but I am checking with the h/w folks on this. Right
now the TRM only describes the procedure for configuring the DPAUX pads
for i2c6. I am also asking about sharing the DPAUX1 pads with i2c4.

Cheers
Jon
Thierry Reding June 20, 2016, 4:38 p.m. UTC | #3
On Mon, Jun 20, 2016 at 10:23:38AM +0100, Jon Hunter wrote:
> 
> On 17/06/16 17:47, Thierry Reding wrote:
> > * PGP Signed by an unknown key
> > 
> > On Fri, Jun 17, 2016 at 01:03:46PM +0100, Jon Hunter wrote:
> >> Populate the 'sor-safe' clock for DPAUX devices on Tegra210 that require
> >> this clock for operation. Update the compatability string for the DPAUX
> >> instance at address 0x545c0000 to be "nvidia,tegra210-dpaux" to ensure
> >> that the 'sor-safe' clock is enabled for this device.
> > 
> > Does the second DPAUX need this, too? I have a vague recollection that
> > they were both slightly different.
> 
> I have assumed so, but I am checking with the h/w folks on this. Right
> now the TRM only describes the procedure for configuring the DPAUX pads
> for i2c6. I am also asking about sharing the DPAUX1 pads with i2c4.

Yes, last time I looked it wasn't documented anywhere with which I2C
controller the other DPAUX shared its pads.

It'd be good to get all of that documented in the TRM.

Thierry
diff mbox

Patch

diff --git a/arch/arm64/boot/dts/nvidia/tegra210.dtsi b/arch/arm64/boot/dts/nvidia/tegra210.dtsi
index 94f780b43037..78bcc87b627d 100644
--- a/arch/arm64/boot/dts/nvidia/tegra210.dtsi
+++ b/arch/arm64/boot/dts/nvidia/tegra210.dtsi
@@ -30,8 +30,9 @@ 
 			reg = <0x0 0x54040000 0x0 0x00040000>;
 			interrupts = <GIC_SPI 11 IRQ_TYPE_LEVEL_HIGH>;
 			clocks = <&tegra_car TEGRA210_CLK_DPAUX1>,
-				 <&tegra_car TEGRA210_CLK_PLL_DP>;
-			clock-names = "dpaux", "parent";
+				 <&tegra_car TEGRA210_CLK_PLL_DP>,
+				 <&tegra_car TEGRA210_CLK_SOR_SAFE>;
+			clock-names = "dpaux", "parent", "sor-safe";
 			resets = <&tegra_car 207>;
 			reset-names = "dpaux";
 			power-domains = <&pd_sor>;
@@ -175,12 +176,13 @@ 
 		};
 
 		dpaux: dpaux@545c0000 {
-			compatible = "nvidia,tegra124-dpaux";
+			compatible = "nvidia,tegra210-dpaux";
 			reg = <0x0 0x545c0000 0x0 0x00040000>;
 			interrupts = <GIC_SPI 159 IRQ_TYPE_LEVEL_HIGH>;
 			clocks = <&tegra_car TEGRA210_CLK_DPAUX>,
-				 <&tegra_car TEGRA210_CLK_PLL_DP>;
-			clock-names = "dpaux", "parent";
+				 <&tegra_car TEGRA210_CLK_PLL_DP>,
+				 <&tegra_car TEGRA210_CLK_SOR_SAFE>;
+			clock-names = "dpaux", "parent", "sor-safe";
 			resets = <&tegra_car 181>;
 			reset-names = "dpaux";
 			power-domains = <&pd_sor>;