@@ -512,6 +512,7 @@
<&clks IMX6UL_CLK_PWM5>;
clock-names = "ipg", "per";
#pwm-cells = <2>;
+ status = "disabled";
};
pwm6: pwm@020f4000 {
@@ -522,6 +523,7 @@
<&clks IMX6UL_CLK_PWM6>;
clock-names = "ipg", "per";
#pwm-cells = <2>;
+ status = "disabled";
};
pwm7: pwm@020f8000 {
@@ -532,6 +534,7 @@
<&clks IMX6UL_CLK_PWM7>;
clock-names = "ipg", "per";
#pwm-cells = <2>;
+ status = "disabled";
};
pwm8: pwm@020fc000 {
@@ -542,6 +545,7 @@
<&clks IMX6UL_CLK_PWM8>;
clock-names = "ipg", "per";
#pwm-cells = <2>;
+ status = "disabled";
};
};
Since PWMs are only useful if they are actually connected to an output pin, let users enable them explicitly in their device trees where they should also set up the pin configuration. Signed-off-by: Lothar Waßmann <LW@KARO-electronics.de> --- arch/arm/boot/dts/imx6ul.dtsi | 4 ++++ 1 file changed, 4 insertions(+)