diff mbox

[6/9] tg3: Reset phy during bringup when using phylib

Message ID 1266022033-3546-7-git-send-email-mcarlson@broadcom.com
State Accepted, archived
Delegated to: David Miller
Headers show

Commit Message

Matt Carlson Feb. 13, 2010, 12:47 a.m. UTC
The driver puts the phy into low-power mode when it releases the device.
If the device were to be reacquired, the phy needs a reset to bring it
back to full powered operation.  This patch allows phylib-enabled
devices to reset the phy.

Signed-off-by: Matt Carlson <mcarlson@broadcom.com>
Reviewed-by: Michael Chan <mchan@broadcom.com>
Reviewed-by: Benjamin Li <benli@broadcom.com>
---
 drivers/net/tg3.c |    3 +--
 1 files changed, 1 insertions(+), 2 deletions(-)
diff mbox

Patch

diff --git a/drivers/net/tg3.c b/drivers/net/tg3.c
index 1c545a8..9c4d88a 100644
--- a/drivers/net/tg3.c
+++ b/drivers/net/tg3.c
@@ -7595,8 +7595,7 @@  static int tg3_reset_hw(struct tg3 *tp, int reset_phy)
 		tg3_abort_hw(tp, 1);
 	}
 
-	if (reset_phy &&
-	    !(tp->tg3_flags3 & TG3_FLG3_USE_PHYLIB))
+	if (reset_phy)
 		tg3_phy_reset(tp);
 
 	err = tg3_chip_reset(tp);