diff mbox series

[3/3] soc/tegra: pmc: Add reset sources and levels on Tegra194

Message ID 20191108153536.3157608-3-thierry.reding@gmail.com
State Accepted
Headers show
Series [1/3] soc/tegra: pmc: Use lower-case for hexadecimal literals | expand

Commit Message

Thierry Reding Nov. 8, 2019, 3:35 p.m. UTC
From: Thierry Reding <treding@nvidia.com>

Tegra194 supports the same reset levels as Tegra186 but extends the set
of reset sources. Provide custom PMC register definitions to account for
the larger field for the reset sources as well as the updated list of
reset sources.

Signed-off-by: Thierry Reding <treding@nvidia.com>
---
 drivers/soc/tegra/pmc.c | 41 +++++++++++++++++++++++++++++++++++++++++
 1 file changed, 41 insertions(+)
diff mbox series

Patch

diff --git a/drivers/soc/tegra/pmc.c b/drivers/soc/tegra/pmc.c
index 32b3e8d9155f..63195281718d 100644
--- a/drivers/soc/tegra/pmc.c
+++ b/drivers/soc/tegra/pmc.c
@@ -2927,6 +2927,43 @@  static const struct tegra_io_pad_soc tegra194_io_pads[] = {
 	{ .id = TEGRA_IO_PAD_AUDIO_HV, .dpd = 61, .voltage = UINT_MAX },
 };
 
+static const struct tegra_pmc_regs tegra194_pmc_regs = {
+	.scratch0 = 0x2000,
+	.dpd_req = 0x74,
+	.dpd_status = 0x78,
+	.dpd2_req = 0x7c,
+	.dpd2_status = 0x80,
+	.rst_status = 0x70,
+	.rst_source_shift = 0x2,
+	.rst_source_mask = 0x7c,
+	.rst_level_shift = 0x0,
+	.rst_level_mask = 0x3,
+};
+
+static const char * const tegra194_reset_sources[] = {
+	"SYS_RESET_N",
+	"AOWDT",
+	"BCCPLEXWDT",
+	"BPMPWDT",
+	"SCEWDT",
+	"SPEWDT",
+	"APEWDT",
+	"LCCPLEXWDT",
+	"SENSOR",
+	"AOTAG",
+	"VFSENSOR",
+	"MAINSWRST",
+	"SC7",
+	"HSM",
+	"CSITE",
+	"RCEWDT",
+	"PVA0WDT",
+	"PVA1WDT",
+	"L1A_ASYNC",
+	"BPMPBOOT",
+	"FUSECRC",
+};
+
 static const struct tegra_wake_event tegra194_wake_events[] = {
 	TEGRA_WAKE_GPIO("power", 29, 1, TEGRA194_AON_GPIO(EE, 4)),
 	TEGRA_WAKE_IRQ("rtc", 73, 10),
@@ -2949,6 +2986,10 @@  static const struct tegra_pmc_soc tegra194_pmc_soc = {
 	.setup_irq_polarity = tegra186_pmc_setup_irq_polarity,
 	.irq_set_wake = tegra186_pmc_irq_set_wake,
 	.irq_set_type = tegra186_pmc_irq_set_type,
+	.reset_sources = tegra194_reset_sources,
+	.num_reset_sources = ARRAY_SIZE(tegra194_reset_sources),
+	.reset_levels = tegra186_reset_levels,
+	.num_reset_levels = ARRAY_SIZE(tegra186_reset_levels),
 	.num_wake_events = ARRAY_SIZE(tegra194_wake_events),
 	.wake_events = tegra194_wake_events,
 };