From: Sarveshwar Bandi <sarveshwarb@serverengines.com> Date: Wed, 23 Dec 2009 20:10:36 +0530 > This change ensures that loopback test command gives up after 4 seconds when > the hardware is not responsive. This could happen if the ports are connected > properly in loopback mode. > > Signed-off-by: Sarveshwar Bandi <sarveshwarb@serverengines.com> Applied. -- To unsubscribe from this list: send the line "unsubscribe netdev" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
Sarveshwar Bandi wrote: > This change ensures that loopback test command gives up after 4 seconds when > the hardware is not responsive. This could happen if the ports are connected > properly in loopback mode. I don't understand the 2nd sentence, did you mean to say that this could happen if the ports are *not* connected properly in loopback mode? Thanks, Jan -- To unsubscribe from this list: send the line "unsubscribe netdev" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
Sarveshwar bandi wrote: > Yes. thats what i meant. > > - Sarvesh OK, thanks for clarifying. Jan -- To unsubscribe from this list: send the line "unsubscribe netdev" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
diff --git a/drivers/net/benet/be_cmds.c b/drivers/net/benet/be_cmds.c index 1b68bd9..a27fdb3 100644 --- a/drivers/net/benet/be_cmds.c +++ b/drivers/net/benet/be_cmds.c @@ -1501,6 +1501,7 @@ int be_cmd_loopback_test(struct be_adapt be_cmd_hdr_prepare(&req->hdr, CMD_SUBSYSTEM_LOWLEVEL, OPCODE_LOWLEVEL_LOOPBACK_TEST, sizeof(*req)); + req->hdr.timeout = 4; req->pattern = cpu_to_le64(pattern); req->src_port = cpu_to_le32(port_num);
This change ensures that loopback test command gives up after 4 seconds when the hardware is not responsive. This could happen if the ports are connected properly in loopback mode. Signed-off-by: Sarveshwar Bandi <sarveshwarb@serverengines.com> --- drivers/net/benet/be_cmds.c | 1 + 1 files changed, 1 insertions(+), 0 deletions(-)